home *** CD-ROM | disk | FTP | other *** search
/ AOL File Library: 4,101 to 4,200 / aol-file-protocol-4400-4101-to-4200.zip / AOLDLs / Business Management / MEDISOFT_ V4.14a Medical Patient / MEDI414A.exe / MAHELP6.TXT < prev    next >
Text File  |  1995-12-08  |  120KB  |  2,050 lines

  1. *61 Create Electronic Claims
  2.                 O P T I O N  I N F O R M A T I O N
  3.         
  4.   Before this operation can be utilized, you must complete the necessary
  5.   "sign-up" procedures with the  appropriate  Insurance  Carrier  and/or
  6.   Clearing  House  to  which  you  will  be  transmitting  your  claims
  7.   electronically. Included with MediSoft is the ability to send your
  8.   claims electronically to an EMC service.  EMC transmission begins with
  9.   selecting the ranges and parameters for creating a file filled with data
  10.   already entered.  At any  time  you  may  press the  [F7]Reprocess EMC
  11.   function  key to access a  pop-up window which will allow you to select
  12.   an existing EMC Batch File for reprocessing.
  13. .PA
  14. >6101
  15.                    F I E L D  I N F O R M A T I O N
  16.  
  17.   Date of Insurances:  Enter the date for the  insurance billing.  You
  18.   may press [Enter] to use the current system date.  When a claim(s) is
  19.   transmitted to the  Insurance Carrier,  this date is  attached to each
  20.   transaction  within the  accepted  claim(s).
  21. .PA
  22. >6102
  23.  
  24.   Range of Chart Numbers:  Enter a beginning and ending  chart number
  25.   separated by a dash to limit EMC claims  creation to specific  chart
  26.   numbers.  If only one  patient is desired, enter that patient's chart
  27.   number.  The default is "All" chart numbers.
  28.  
  29.   Press [F6]Search to access Patient Search window.  You may exclude
  30.   patients from EMC processing by setting the 'Is Patient' field  in
  31.   the Patient Information option to "No".
  32. .PA
  33. >6103
  34.  
  35.   Range of Billing Codes:  Enter a beginning and ending billing code
  36.   separated by a dash to limit claims to patients  with a  specific
  37.   billing code.  Press  [Enter]  to include  patients  regardless of
  38.   billing  code.  If you are using Just Claims as a stand alone 
  39.   package, this field will be skipped.
  40. .PA
  41. >6104
  42.  
  43.   Range of Indicators:  Enter a beginning  and  ending indicator
  44.   separated  by a dash to limit creation of claims to patients with a
  45.   specific indicator. Press [Enter] to include  patients  regardless  of
  46.   indicator.  If you are using Just Claims as a stand alone package,
  47.   this field will be skipped.
  48. .PA
  49. >6105
  50.  
  51.   Range of Providers:  Enter a beginning and ending provider number
  52.   separated by a dash to limit  creation of  claims to  specific
  53.   providers.  Press [Enter] to include all providers.  Press [F6]Search
  54.   to access the  Provider Search window.
  55. .PA
  56. >6106
  57.  
  58.   Range of Service Dates:  Enter a beginning and ending date separated
  59.   by a dash to limit the claim file created containing transactions in a
  60.   specific date range. The default is all  current  unbilled transactions
  61.   regardless of dates.
  62.  
  63.   To include  history,  enter a date on or before the End of Period Date
  64.   as defined in the Setup Office Information option.
  65. .PA
  66. >6107
  67.  
  68.   Range of Procedure Codes:  Enter a beginning and ending procedure code
  69.   separated by a  dash to limit each claim to certain procedure codes.
  70.   Press [Enter] to include all procedure codes.  You may wish to use this
  71.   feature to print claims for procedures for which you must  accept
  72.   assignment, or to print only procedure which you are allowed to bill.
  73.   You may also exclude procedure codes by setting the 'Patient Only
  74.   Responsible' field of Procedure Code Information option to "Yes".
  75.   Press [F6]Search  to access the Procedure Code Search window.
  76. .PA
  77. >6108
  78.  
  79.   Range of Balances:  Enter a beginning and ending  balance amount
  80.   separated by a dash to limit claim  creation to only those patients who
  81.   have entries that have not been billed, to insurance whose total falls
  82.   in the range specified.  Use this  feature to  delay  billing  entries
  83.   to a patients' insurance carrier  until  the  unbilled  balance
  84.   reaches  a  specific threshold.
  85. .PA
  86. >6109
  87.  
  88.   EMC Batch File Comment:  Enter up to  30  characters  of free  form
  89.   text that  will be  used to uniquely  identify  this  EMC  Batch  File
  90.   from other files created on the same date, for the same Carrier, etc.
  91.   This information is not transmitted.
  92.  
  93.   If you are using the  security  option  available within MediSoft, the
  94.   current  User  ID  will  be  defaulted.
  95. .PA
  96. >6110
  97.  
  98.   Crossover Claims:  Select the default, "Yes" and secondary insurance
  99.   information will be included in the  EMC file.  Select "No", and no
  100.   secondary  information will be reported.  You may exclude individual
  101.   insurance companies from reporting as secondary payers one of two ways:
  102.  
  103.   1. Set the Claim Print field on the Insurance Information option to "P"
  104.      for PAPER.
  105.   2. Set the  Delay Secondary Billing  field on the Insurance Information
  106.      option to "Yes".
  107. .PA
  108. >6111
  109.  
  110.   Rebill Transactions:  Select the default "Yes", and the system will
  111.   ignore billing dates for acceptable transactions.  If you select "No",
  112.   the system will only include transactions which have NOT previously
  113.   been marked as billed.  Note: In PRODuction mode, when electronic
  114.   claims are  rejected; you should not need to enter "Yes" for  Rebill
  115.   Transactions.  Refer to the Mark Claim Status option to remove primary
  116.   and secondary billing dates on rejected transaction. This will cause
  117.   them to be treated as unbilled entries, thus eliminating the need to
  118.   rebill.
  119. .PA
  120. >6112
  121.  
  122.   Primary Rebilling Dates:  If you selected "No" to the Rebill
  123.   Transactions prompt, this field will be skipped. Enter a beginning and
  124.   ending date separated by a dash in to limit previously billed
  125.   transactions to those billed within the range of dates. The default is
  126.   all billed transactions.
  127.  
  128.   Note:  If a transaction has NOT been previously billed, this range of
  129.   dates will be ignored.
  130. .PA
  131. >6113
  132.  
  133.   Verification Report:  Select the default "Yes", and the resulting EMC
  134.   Batch file will have a status of "Verify", and be automatically tagged
  135.   for Verification Report printing. Enter "No", and the resulting EMC
  136.   Batch file will have a status of "Transmit", and be automatically
  137.   tagged for transmission.
  138. .PA
  139. >6114
  140.  
  141.   Single EMC Receiver:  Enter the Direct Receiver/Insurance Carrier
  142.   number for the desired EMC Receiver.  Selecting a receiver in this
  143.   field initiates EMC Batch File creation for this EMC Receiver only.
  144.   The EMC Receivers listed in the GROUP EMC RECEIVER SELECTION window
  145.   will be ignored.  Press [F6]Search to access the EMC Receiver Lookup
  146.   window.  Press [F8]EMC Settings to access the Edit EMC Settings
  147.   window.
  148.   Leave  blank  to  access  the  GROUP  EMC  RECEIVER  SELECTION  window.
  149. .CO Single EMC Receiver
  150.  
  151.   If the selected  Direct Receiver/Insurance Carrier code is defined as a
  152.   Direct Receiver on the  Change EMC Settings screen,  claims transaction
  153.   processing  will  be  restricted  to  patient  charts with an identical
  154.   primary insured's number.  If the selected EMC Receiver is defined as a
  155.   Clearing House,  you will be  given the  ability  to  enter  a range of
  156.   Insurance Company numbers.
  157. .CO Single EMC Receiver
  158.  
  159.   Any EMC Receiver number you attempt to select on this screen will
  160.   require that you have defined an Insurance Company record in the
  161.   Insurance Information option, and a Direct EMC Receiver record in the
  162.   Change  EMC  Settings  option.
  163.  
  164.   EMC services requires an Insurance Company record.  Equifax is already
  165.   assigned 0000 as the Direct Receiver number for your convenience.  When
  166.   establishing a  Clearing House remember  that the Insurance Company
  167.   record is for reference purposes only,  and that you should NEVER
  168.   assign the Clearing House number to a Patients Primary, Secondary or
  169.   Tertiary  Insurance  Number.
  170. .CO Single EMC Receiver
  171.                 IMPORTANT MESSAGE ABOUT EMC RECEIVERS
  172.  
  173.   If  you are  going to  file claims  for an insurance  carrier through a
  174.   Clearing House,  DO NOT set up the insurance carrier in the  Change EMC
  175.   Settings option.  When an insurance carrier has been defined in EMC
  176.   Change Settings it is treated like a Direct EMC Receiver.
  177.  
  178.   When  you do  select your  Clearing House for  EMC Batch File creation,
  179.   any  patient who has their primary insurance carrier defined in the EMC
  180.   Settings,  WILL  BE  SKIPPED.
  181. .CO Single EMC Receiver
  182. .PA
  183.                  IMPORTANT MESSAGE ABOUT CLEARING HOUSES
  184.  
  185.   Just  because  you  have  defined  insurance  company  records  for the
  186.   Clearing Houses  to  which  you will be submitting  does  not  mean
  187.   that  these  are  insurance  companies.  DO NOT, repeat DO NOT enter an
  188.   Insurance Company Number associated with any  Clearing House  as the
  189.   primary,  secondary  or  tertiary insurance company for any of your
  190.   patients.  The Clearing Houses are setup in the Insurance  Company
  191.   File for  reference  purposes  only.
  192. .PA
  193. >6115
  194.  
  195.   Insurance Company Range:  If you selected an EMC Receiver, defined as
  196.   a Direct Receiver, this this  field  will  be  skipped.  Press [Enter]
  197.   for  the  default  of  all  insurance  companies.  Enter a beginning
  198.   and ending insurance carrier number,  separated by a dash to limit
  199.   claims  creation  to patients  whose  primary insurance carrier falls
  200.   within  the  selected Range of Insurance Companies.
  201. .PA
  202. >XWIN61R
  203.               R E C R E A T E   E M C   B A T C H   F I L E
  204.  
  205.   This  window  is  used  to  select  an  existing  EMC  Batch  File  for
  206.   reprocessing.  If you locate an error on the Verification Report, or
  207.   rejected claims in Mark Claim Status and you want to reprocess those
  208.   claims, select the original EMC Batch File for reprocessing.
  209.  
  210.   The actual RECREATE function does not mean that those original claims
  211.   will physically be  reprocessed.  What actually happens is that  the
  212.   ranges used  when  you  created the  original  EMC Batch File,  will be
  213.   used  for  the  recreation  process.
  214. .CO Recreate EMC Batch File
  215.  
  216.   There  are  several  points  of  interest  regarding  recreation:
  217.   1. If the transaction within the ranges have received a primary billing
  218.      date since the original creation, and the Rebill Transactions field
  219.      is "No", the transactions will NOT be included in the new EMC Batch
  220.      File.
  221.   2. If you have entered new transactions that have not been billed, they
  222.      may  be  included if they fall within the previously defined ranges.
  223.   3. If  a  Month  End  process  has  been  performed  since the original
  224.      creation,  and the Range of Service Dates does not fall on or before
  225.      the End of Period Date,  then the transactions  will not be included
  226.      for  the  recreation  of  the  claims.
  227. .CO Recreate EMC Batch File
  228.  
  229.   The  following  are  situations  when  you  may  want  to  recreate  an
  230.   existing  EMC  Batch  File:
  231.   1) You  have  located  an  error  before  transmitting  the  EMC  file.
  232.   2) The  EMC  Receiver  rejected  the  entire  EMC  Batch  File.
  233.   3) You have used "All" for the ranges,  and desire to have an EMC Batch
  234.      File  created  based  on  all  current  unbilled  entries.
  235. .CO Recreate EMC Batch File
  236.  
  237.   The following are items that will negate the possibility of recreating:
  238.   1) You  used  an  incorrect  range setting during the original creation
  239.      process.
  240.   2) You  did  not  select  Rebill Transactions in the original creation,
  241.      and  the  transactions  have  since  been  billed.
  242.   3) You did not use a  Range of Service Dates  in the original creation,
  243.      and  now  you  need  to  bill  from  history.
  244. .CO Recreate EMC Batch File
  245.   While you are in the scrolling window, use the arrow keys to high- 
  246.   light the file to be selected.  You may also use  Home, End, PgUp and
  247.   PgDn.  Other keys that function within the window are listed at the 
  248.   bottom of the screen.
  249.   
  250.   Esc       Exits the window, and positions the cursor at the last field.
  251.   Enter     Selects  the  currently  highlighted EMC Batch File.
  252.   F1        MediSoft  Help  Window.
  253.   F2        Prints a utility  EMC Ledger  for the contents of the window.
  254.   F4        Alternates between single or double line  (detail) view mode.
  255.   F6        Changes the current status of the highlighted EMC Batch File.
  256.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit
  257.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  258. .PA
  259. >XWIN61CR
  260.                   E M C   C R E A T I O N   R E S U L T S
  261.  
  262.   This window lists the results of the recently completed EMC Batch File
  263.   creation process.  Each line listed  within  this  window represents an
  264.   EMC  Receiver  that  was  scheduled  for  EMC  Batch  File  creation.
  265.   The  PROCESS  column indicates  whether  the  listed  EMC Receiver  was
  266.   included in the EMC Batch File creation process.  If the PROCESS column
  267.   reads "NO",  the CLAIMS column will read "0" and the EMC Batch Filename
  268.   will  read  "Not Selected".
  269.  
  270.   If the PROCESS column reads "YES",  then the CLAIMS column will display
  271.   the actual number  of  claims processed for the indicated EMC Receiver.
  272.   The  EMC  Batch  Filename  column  will  display  the  full  filename.
  273. .CO EMC Creation Results
  274.  
  275.   You  do  have  the  ability  to delete an EMC Batch File at this point.
  276.   Press the  [F10]Delete  key  to  delete the highlighted EMC Batch File.
  277.   This will not adversely effect your data.  Any claims created within
  278.   the deleted  EMC Batch File  will be included automatically the next
  279.   time the  EMC Receiver is selected (included) for EMC Batch File
  280.   creation (provided user defined ranges do not excluded those
  281.   transactions).  After you delete an  EMC Batch File, the CLAIMS column
  282.   will read "0", and  the  EMC  Batch  Filename  column  will  read
  283.   "NO  EMC  BATCH  FILE  CREATED!"
  284. .CO EMC Creation Results
  285.  
  286.   If the PROCESS column reads "YES"  but the CLAIMS column reads  "0" and
  287.   the  EMC  Batch  Filename  reads  "NO  VALID  EMC  CLAIMS  FOUND", then
  288.   NO ACCEPTABLE  PATIENTS/TRANSACTIONS  WERE FOUND.  Please refer to the
  289.   "Little Blue Book" for a troubleshooting checklist.
  290. .PA
  291. >XWIN61RS
  292.       G R O U P   E M C   R E C E I V E R   S E L E C T I O N
  293.  
  294.   This window is accessed when you leave the Single EMC Receiver field
  295.   blank, indicating automatic creation of an EMC Batch File for one
  296.   or more EMC Receivers.  Use the arrow keys to position the highlight
  297.   on an  EMC Receiver.  You can also press [Enter]  to move  the  high-
  298.   light  to  the next EMC Receiver.  Press the [Space Bar] to switch the
  299.   PROCESS column  setting  between  "YES"  and  "NO".  Press  the
  300.   [F5]Switch All key to switch the  PROCESS  column  settings  of  all
  301.   the EMC Receivers listed  in  the window.  Press [F3]CREATE EMC  to
  302.   accept  the  PROCESS column  settings  and  to  begin  EMC  Batch  File
  303.   creation  for  receivers  with  a  PROCESS  column  setting  of  "YES".
  304. .CO Group EMC Receiver Selection
  305.  
  306.   If  the  MODE  column  for  a  listed EMC Receiver ID set to TEST,  the
  307.   PROCESS  column  will  be  defaulted to "NO".  If the MODE column for a
  308.   listed  EMC Receiver ID  set  to  PROD,  the  PROCESS  column  will  be
  309.   defaulted  to  "YES".
  310. .PA
  311. >XWIN61RC
  312.                   B A T C H   F I L E   C O M M E N T
  313.  
  314.   The  EMC Batch File  you have selected for  recreation has already been
  315.   transmitted to the EMC receiver.  This recreation process will merely
  316.   use the original batch file settings to create a new EMC Batch  File.
  317.  
  318.   Enter a Comment  for this new  EMC Batch File up to  30 characters  of
  319.   free form text that  will be used to uniquely identify this EMC Batch
  320.   File from others on the same date, for the  same  EMC  Receiver,  etc.
  321.   The  Comment  for  the  original  EMC  Batch  File  is  your  default.
  322. .PA
  323. >XWIN61SC
  324.         B E G I N   E M C   B A T C H   F I L E   C R E A T I O N
  325.   
  326.   You are being prompted now to accept the current range settings for
  327.   single or group EMC Receiver or to accept the currently selected EMC
  328.   Batch File  for  recreation.
  329.  
  330.   Press  the  letter  "Y" yes to begin the EMC Batch File Creation
  331.   process or "N" for no to return to the last field/window  accessed.
  332. .PA
  333. >XWIN61DS
  334.                   D E L E T E   E M C   B A T C H   F I L E
  335.   
  336.   You have chosen to delete  the currently  highlighted  EMC Batch File
  337.   that was just  created.  The only effect  deleting this  EMC Batch File
  338.   will have, is that it will be like you never created this file in the
  339.   first  place.
  340.  
  341.   WARNING:  If  the  highlighted  EMC Batch File  represents a  RECREATED
  342.   EMC Batch File that was never transmitted:  The original EMC Batch File
  343.   has already  been replaced  and no  longer exists.  If you  delete this
  344.   EMC Batch File, the original will no longer exist and you will lose all
  345.   record of this EMC Batch File.
  346. .PA
  347. *62 Verification Report
  348.                O P T I O N  I N F O R M A T I O N
  349.  
  350.   One advantage to a  "paper claim"  is one's ability to view the printed
  351.   information  prior to mailing the  "paper claim".  It is very important
  352.   that  you  are  able  to  visually  check  your  information  prior  to
  353.   submitting it for payment.  MediSoft allows  you to generate  just such
  354.   an "Edit List".  The Verification Report allows you to manually analyze
  355.   claim  information  before it is  submitted  for payment.  This process
  356.   helps you  minimize on the number of  "rejections".  A  "rejection"  is
  357.   what happens  when the  insurance company cannot understand one or more
  358.   pieces of information on a claim.
  359. .CO Option Information
  360.   The reasons  are many,  but the  result is  the same.  Refusal  to pay.
  361.   Use this  Verification Report to  locate any critical  problem areas in
  362.   your  claim data.  If you are concerned  about replacing  "paper claim"
  363.   waste with  Verification Report waste,  remember to send your report to
  364.   display, or a report file.
  365.  
  366.   This  option produces a listing  of  all claims  stored within  an  EMC
  367.   Batch File.  The  information  is reported  by provider,  then patient.
  368.   The individual patient has their own claim for each provider. A patient
  369.   may have multiple claims for any given provider if the line items for a
  370.   patient,  for  a  provider  reference  more  than  four  (4)  different
  371.   diagnoses  codes.
  372. .CO Option Information
  373.   Total claim amounts,  the number of claims and the number of line items
  374.   (or transactions)  are listed  for each provider,  and for  the report.
  375.   Totals for  each insurance  type are listed at the end of  the  report.
  376.   It would be very ineffective to list all the information within the EMC
  377.   Batch File for editing purposes,  so only the "primary" information has
  378.   been chosen to be included.   A Verification Report without errors does
  379.   not mean the EMC Batch File will be accepted.
  380. .PA
  381. >6201
  382.  
  383.   Verification Report Type:
  384.   Enter a 1, 2, 3 or 4 to select a specific type of  Verification Report.
  385.   1: Summary  - Print a single line for each claim.
  386.   2: Standard - Print basic patient and insurance information.
  387.                 Print detailed transaction information.
  388.   3: Detailed - Print detailed patient, insurance, facility and referring
  389.                 provider information.
  390.                 Prints detailed transaction information.
  391.   4: Raw Data - Print the contents of the EMC TRANSMISSION FILE.
  392.                 This is a file "dump" and is not formatted for user
  393.                 interpretation. 
  394. .PA
  395. >6202
  396.  
  397.   Print Insurance Summary: Following each EMC Batch File Verification
  398.   Report is the Insurance Type Summary page.  This  optional  document
  399.   summarizes claim amounts by Insurance Carrier Type: Commercial/NEIC,
  400.   Medicaid Phys, Medicare/Medicaid, Medicare, Blue Cross/Blue Shield,
  401.   Blue Cross  Physician, Champus  or  Workmans  Compensation.
  402.   Select  "Y"  yes to  include this page after each Verification Report.
  403.   Select "N" for no to  exclude  this  page.
  404. .PA
  405. >XWIN62T
  406.                   T A G   E M C   B A T C H   F I L E S
  407.  
  408.   This window is used to modify the  "selection list"  of EMC Batch Files
  409.   that  will  have  a  Verification  Report  printed. When an EMC Batch
  410.   File is created, and the Verification Report is set to YES,  the
  411.   resulting EMC Batch File(s) will be tagged and ready for printing.
  412.   You would not need to modify the settings in the TAG column.  It would
  413.   be more likely that you may need to reprint a Verification  Report.
  414.  
  415.   In that event,  this  window  allows you to change the  YES/NO  setting
  416.   in the TAG column.  By pressing the SPACEBAR you toggle the TAG setting
  417.   for  the  highlighted  EMC Batch File.  By  pressing  the [F5] key, you
  418.   toggle  the  TAG  setting  for  ALL  the  EMC  Batch  Files.
  419. .CO TAG EMC Batch Files
  420.  
  421.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  422.   highlight and select a file.  You may also use  Home,  End,  PgUp and PgDn.
  423.   Other keys that  function within the window are listed at the bottom of
  424.   the  screen.
  425.   Esc       Exits the window, and positions the cursor at the last field.
  426.   Enter     Begin the Verification Report printing process.
  427.   Space     Change the  TAG  setting for the  highlighted EMC Batch File.
  428.   F1        MediSoft  Help  Window.
  429.   F2        Prints a utility  EMC Ledger  for the contents of the window.
  430.   F4        Alternates between single or double line  (detail) view mode.
  431.   F5        Change  the  TAG  setting  for all of the  EMC  Batch  Files.
  432.   F6        Changes the current status of the highlighted EMC Batch File.
  433.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit
  434.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  435. .PA
  436. *63 Transmit Electronic Claims
  437.                  O P T I O N  I N F O R M A T I O N
  438.  
  439.   You have by now, created one or more EMC Batch Files. You may have also
  440.   verified their contents  using the  Print Verification Report.  Now you
  441.   are ready to  transmit the  EMC Batch File(s)  to the  appropriate  EMC
  442.   receiver(s).  The concept of  transmitting  EMC Batch Files  is simple:
  443.   Dial a carrier, give them your ID, request a transmission, transmit the
  444.   file, request any return files then say goodbye. 
  445. .CO Option Information
  446.   These is no user interface required, beyond that of selecting which EMC
  447.   Batch Files  to transmit.  For the most part,  the job of selecting the
  448.   EMC Batch Files is also handled automatically.  All you  need to  do is
  449.   initiate  the  transmission  process.  Of course, there are exceptions.
  450.   Sometimes  "fatal"  errors  occur.  Errors  can  be  anything  from  an
  451.   incorrectly  configured  modem,  to noise on the  telephone line.  When
  452.   certain errors occur, MediSoft notifies you of the error via the "Error
  453.   Message Window".  This window  will remain on the screen until a key is
  454.   pressed.  Other  than  that,  transmission  is  automatic.
  455. .CO Option Information
  456.   MediSoft  Direct  comes  standard  with  the  ability  to  file  claims
  457.   electronically  with  EMC services.
  458.   You have direct options too.  You may use one of the  included clearing
  459.   houses, or you may submit directly to the EMC receiver using a MediSoft
  460.   EMC  Direct  module (depending  upon  availability).
  461.   All  EMC  functionality  is provided through the means of Format Files.
  462.   These  Format  Files  contain  all  information  and  instructions  for
  463.   MediSoft Direct  to  correctly  analyze your data,  create an EMC Batch
  464.   File conforming to the EMC receivers guidelines, transmit the EMC Batch
  465.   File and  potentially update  your  system  with  Electronic Remittance
  466.   Information on your filed claims. Please, contact your MediSoft  dealer
  467.   for  information  on  purchasing  MediSoft  EMC  Direct  Format  Files.
  468. .CO Option Information
  469.        P R E - R E Q U I S I T E S  T O  T R A N S M I T T I N G
  470.  
  471.   In  order  to  successfully  send your  electronic claims to a Clearing
  472.   House  or  directly  to  an  EMC Receiver  you need to be sure you have
  473.   have  correctly  done  the  following:
  474.   1. Entered  the  EMC Receiver  or  Clearing House  into  the  Insurance
  475.      Information  screen  of  MediSoft.
  476.      NOTE:  You DO NOT need to setup Equifax in the Insurance Information
  477.      screen of  MediSoft if you will be using the default  0000 receiver.
  478. .CO Option Informatio
  479.   2. Defined settings for the  EMC receiver in the EMC Settings option of
  480.      MediSoft.
  481.      NOTE:  You  must  setup  Equifax  in  the  EMC  Settings  File.
  482.      {Please  see  IMPORTANT EMC  SETTINGS MESSAGE  for  some  additional
  483.      information  following  this  help.}
  484.   3. Established all necessary  MediSoft data  {i.e. Patients, Codes,...}
  485.   4. Generated  Patient  Transactions  using  (3-1)  Transaction  Entry.
  486.   5. Created an  EMC Batch File using the Create Electronic Claims option
  487.      of MediSoft.
  488.   6. Possibly  printed  Verification  Reports  for  the  EMC Batch Files.
  489. .CO Option Information
  490.       A D D I T I O N A L  T R A N S M I T  I N F O R M A T I O N
  491.  
  492.   Direct Receiver/Insurance Carrier  connections  vary greatly.  Some are
  493.   as simple as dial up,  upload and  disconnect. Others are full featured
  494.   Bulletin Board Systems  in which a  lengthy series of  logon procedures
  495.   and  menu  options  are  required  before  a  file  may be transmitted.
  496.   Either way,  each individual carriers requirements have been met within
  497.   the  EMC  receivers  MediSoft  EMC  Direct Format File.  Some receivers
  498.   provide instant EMC Batch File submission results in the form of a Post
  499.   Transmission Report.  Whenever possible, MediSoft automatically returns
  500.   this  file  to  your  system.
  501. .CO Option Information
  502.   MediSoft also makes  concessions  for  those  receivers  who  send back
  503.   multiple  files, such as  EOMB's  and  ERN's. Some of these files which
  504.   are  "downloaded"  contain information  on the  acceptance/rejection of
  505.   previously submitted claims. When possible, MediSoft will analyze these
  506.   files  and  update  the  MediSoft  data  for  you.  In many cases,  the
  507.   "downloaded"  files  cannot  be,  consistently,  interpreted.  In other
  508.   cases, there are no "downloaded" files.  In either of these cases,  you
  509.   as the user are  required to  manually perform  any  subsequent billing
  510.   functions.  Please read  the  MediSoft Direct  manual  for  each of the
  511.   carriers you have installed for information on the specific results you
  512.   may  expect  during  the  transmission  process.
  513. .PA
  514. >6301
  515.                   T R A N S M I S S I O N   D E L A Y
  516.  
  517.   This function gives you the  ability to  suspend the  transmission of a
  518.   group of one or more  EMC Batch Files that have a status of "Transmit".
  519.   This is helpful when the  EMC receiver(s) experience an overload during
  520.   normal business hours,  resulting in BUSY signals and slow connections.
  521.   Some EMC receivers may assign you a transmission "slot" or time window
  522.   in which  your  EMC  Batch  Files  must  be  transmitted.
  523.  
  524.   This delay feature does require  exclusive access of the computer while
  525.   in the delay or countdown mode.  Once you set the start time,  MediSoft
  526.   will  display  an  "EMC  Transmission Delay"  countdown  screen  saver.
  527.   You  may  interrupt  this  delay  event  by  pressing  the  [Esc]  key.
  528. .CO Option Information
  529.   Start Time:  Enter the desired transmission process starting time.
  530.   Enter the  hour, followed by the minutes, followed by a "p" or "a" to
  531.   indicate PM or AM.
  532.  
  533.   If the time you enter is earlier than the current time, the system will
  534.   delay until the specified time the following day. Thus, you may specify
  535.   times as obscure as 3 or 4  o'clock in the morning, should that become
  536.   necessary.  You may return to the EMC Batch File selection windows by
  537.   pressing the [Esc] key.
  538. .PA
  539. >XWIN63
  540.                   T A G   E M C   B A T C H   F I L E S
  541.  
  542.   This window is used to modify the "selection list" of EMC Batch Files
  543.   that will be included in the transmission process.  When an EMC
  544.   Batch File is created, and the Verification Report field on the Create
  545.   Electronic Claims  screen is set to  NO,  the resulting EMC Batch
  546.   File(s) will be tagged and ready for transmission.  Otherwise, a
  547.   Verification Report would have been required for the EMC Batch File to
  548.   have a status of Transmit. In either case, the EMC Batch File will now
  549.   be tagged for transmission.  You normally do not need to  modify any of
  550.   the TAG column settings, unless a transmission failed or was abandoned.
  551. .CO Option Information
  552.  
  553.   In that event,  this  window  allows you to change the  YES/NO  setting
  554.   in the TAG column.  By pressing the SPACEBAR you toggle the TAG setting
  555.   for  the  highlighted  EMC Batch File.  By pressing the [F5] key, you
  556.   toggle  the  TAG  setting  for  ALL  the  EMC  Batch  Files.
  557.  
  558.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  559.   highlight and select a file.  You may also use Home, End, PgUp and PgDn.
  560.   Other keys that  function within the window are listed at the bottom of
  561.   the  screen.
  562. .CO Option Information
  563.  
  564.   Esc       Exits the window,  and  returns to the MediSoft  Sub-Menu.
  565.   Enter     Immediately initiate the EMC Batch File Transmission process.
  566.   Space     Change the  TAG  setting for the  highlighted EMC Batch File.
  567.   F1        MediSoft  Help  Window.
  568.   F2        Set MediSoft into a user defined Transmission Delay process.
  569.   F4        Alternates between single or double line  (detail) view mode.
  570.   F5        Change  the  TAG  setting  for all of the  EMC  Batch  Files.
  571.   F6        Changes the current status of the highlighted EMC Batch File.
  572.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit
  573.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  574. .PA
  575. >SPEC630
  576.                  U S E R   D E F I N E D   F I L E N A M E
  577.  
  578.   The  system  is  requesting  that  you  supply  a valid D O S Filename.
  579.   You may indicate a drive and a path that are different from the current
  580.   directory.  You may also specify a  filename  different from that which
  581.   is  displayed.
  582.  
  583.   WARNING:  The User Defined File will  overwrite  any existing file with
  584.   the  same  name.
  585. .CO Option Information
  586.  
  587.   The system  is  displaying what it calls the "Most Logical Default".
  588.   Since MediSoft  utilizes  a  file  naming convention for its EMC files
  589.   based upon  the day of the year, the number of files created within the 
  590.   same day, a "file type" character identifier and the data set,  It is 
  591.   now suggesting that you do the same. This will give you a way of 
  592.   "attaching" files to their related  EMC Batch Files by way of the file 
  593.   name.  The system initially defaults a "file type" character of "K".  
  594.   MediSoft is reserving the first ten (10) alphabetic letters for system 
  595.   and control information that may be required in the future.
  596. .CO Option Information
  597.  
  598.   If you accept the  "Most Logical Default",  MediSoft will  increment to
  599.   the next letter in the alphabet.  Giving you the  ability to receive up
  600.   to sixteen  (16)  files to be "attached" to a single Claims Batch File.
  601.   NOTE:  You must make an entry here.  You may not press [Esc] to abort !
  602. .PA
  603. *64 Post Transmission Report
  604.                   T A G   E M C   B A T C H   F I L E S
  605.  
  606.   This window is used to modify the  "selection list"  of EMC Batch Files
  607.   that  will  be  included  in  for  Post  Transmission  Report printing.
  608.   When an  EMC Batch File is successfully transmitted,  the status of the
  609.   file will be changed to either Mark or Audit. The status will be set to
  610.   Audit when an online claim status report is available - and MediSoft is
  611.   able to interpret that file.  Otherwise, claim status  determination is
  612.   the responsibility of the user.  Regardless of a Mark or Audit status,
  613.   the Batch File will be tagged for Post Transmission Report printing.
  614. .CO TAG EMC Batch Files
  615.   This does not  necessarily mean  that a recently  transmitted EMC Batch
  616.   File has a  Post Transmission Report  waiting  to be printed.  Some EMC
  617.   receivers  will have a report  that was used to  perform  claim  status
  618.   determination. In that case, the Post Transmission will be printed
  619.   during the Audit/Edit Report printing, making this function unnecessary.
  620.   Some  EMC receivers  will require you to manually collect the  Post
  621.   Transmission Report from the BBS some time after transmission (using
  622.   the Carrier BBS Connection screen).  In that case you may be required
  623.   to print the Post Transmission Report from the Print Text File option
  624.   screen  within  the  MediSoft  Utilities  Menu.
  625. .CO TAG EMC Batch Files
  626.  
  627.   And  still  some  other  EMC receivers may not supply any form of  Post
  628.   Transmission  Report  that can  be acquired "electronically".  Most EMC
  629.   receivers do provide an immediate Post Transmission Report which may be
  630.   printed  out  from this screen.  Check within the  MediSoft  EMC Direct
  631.   manual for your EMC Receiver(s) for details on Post Transmission Report
  632.   availability. You normally do not need to modify any of the TAG  column
  633.   settings,  unless you need a  reprint of a  previously  printed report.
  634.   In that event,  this  window  allows you to change the  YES/NO  setting
  635.   in the TAG column.  By pressing the SPACEBAR you toggle the TAG setting
  636.   for  the  highlighted  EMC Batch File.  By  pressing the [F5] key, you
  637.   toggle  the  TAG  setting  for  ALL  the  EMC  Batch  Files.
  638. .CO TAG EMC Batch Files
  639.  
  640.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  641.   position the highlight.  You may also use  Home,  End,  PgUp and PgDn.
  642.   Other keys that  function within the window are listed at the bottom of
  643.   the  screen.
  644. .CO TAG EMC Batch Files
  645.   Esc       Exits the window,  and  returns  to  the  MediSoft  Sub-Menu.
  646.   Enter     Begins  the  Post  Transmission  Report  printing  process.
  647.   Space     Change the  TAG  setting for the  highlighted EMC Batch File.
  648.   F1        MediSoft  Help  Window.
  649.   F2        Prints a utility  EMC Ledger  for the contents of the window.
  650.   F4        Alternates between single or double line  (detail) view mode.
  651.   F5        Change  the  TAG  setting  for all of the  EMC  Batch  Files.
  652.   F6        Changes the current status of the highlighted EMC Batch File.
  653.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit
  654.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  655. .PA
  656. *65 Mark Claim Status
  657.                  O P T I O N  I N F O R M A T I O N
  658.  
  659.   After an  EMC Batch File  has been successfully  transmitted to the EMC
  660.   receiver,  MediSoft updates all the transactions within each claim with
  661.   a primary  (and possibly a secondary)  billing  date.  If  your  Office
  662.   Information has been setup to create Billing Notes,  these will also be
  663.   created.  An  Insurance Analysis  record is also output for each claim.
  664.   By  marking  billing  dates  on  the  transactions,  MediSoft  will now
  665.   exclude  those transactions  from further  MediSoft Billing operations,
  666.   unless  specifically  told  (rebill transactions).
  667. .CO Option Information
  668.   In the world of electronic claims,  transmitting an EMC Batch File does
  669.   mean those claims will be paid.  Electronic claims,  like paper claims,
  670.   may  be  rejected  after  being  received  by  the  EMC  receiver.
  671.   This means that until the EMC receiver  (or insurance company) actually
  672.   accepts or rejects  those claims,  they are really  "pending".  If  the
  673.   EMC receiver makes available an online claim status file that  MediSoft
  674.   is able  to  consistently interpret,  the process of  marking claims as
  675.   accepted or rejected is performed immediately after the transmission in
  676.   an  automated  fashion.  Thus  making  use  of this option unnecessary.
  677.   The  Equifax  electronic  interface  functions  in  this  manner.
  678. .CO Option Information
  679.   Equifax  EMC  Batch  Files  are  given  a  status of  Audit immediately
  680.   following transmission.  Most other  EMC  receivers  do  not  have this
  681.   functionality.  Thus the  need to  manually  mark claims as accepted or
  682.   rejected.  Some EMC receivers  will also  reject individual line items,
  683.   but  still  pay  on  a  claim.  This  option  also  handles  line  item
  684.   transaction  rejections.
  685.  
  686.   When a claim is rejected  (or an individual transaction), MediSoft will
  687.   remove the  primary  and  secondary  billing dates  for the appropriate
  688.   transactions.  MediSoft  will  also  output  an  Insurance  Analysis
  689.   adjustment record  to offest the original entry when the EMC Batch File
  690.   was  transmitted.
  691. .PA
  692. >XWIN65
  693.             S E L E C T   E M C   B A T C H   F I L E S
  694.  
  695.   This  window  is  used  to  select an  EMC Batch  File for claim status
  696.   determination.  The  EMC Batch Files  listed all have a status of Mark.
  697.   These are  files which  have been  transmitted,  but MediSoft could not
  698.   perform  any  immediate  online  claim  status  determination.
  699. .CO Select EMC Batch Files
  700.  
  701.   All claims within an EMC Batch File with a status of Mark are initially
  702.   set to PENDING. This is a temporary status.  It is up to you to acquire
  703.   some form of claim status report from the EMC receiver or the insurance
  704.   carrier, in order to change the PENDING to either ACCEPTED, REJECTED or
  705.   OK:PAPER  (which means accepted, but forwarded on  paper to the payer).
  706.   Only when all the claims within the  EMC Batch File  have been switched
  707.   will MediSoft  "process"  the rejected  transactions and change the EMC
  708.   Batch File status to Audit.  The existence of an EMC Batch File in this
  709.   window indicates  that at  least one  claim for  the batch  still has a
  710.   status  of  PENDING.
  711. .CO Select EMC Batch Files
  712.  
  713.   It is possible  to  perform service line item rejections as well.  Once
  714.   you have selected an  EMC Batch File,  you may  pop up  a window of the
  715.   service line items for each claim.  Claims which have rejections at the
  716.   line item  level will show  a  status of  PARTREJ  (Partial Rejection).
  717. .CO Select EMC Batch Files
  718.  
  719.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  720.   highlight and select a file.  You may also use Home, End, PgUp and PgDn.
  721.   Other keys that  function within the window are listed at the bottom of
  722.   the  screen.
  723.   Esc       Exits the window, and positions the cursor at the last field.
  724.   Enter     Selects  the  currently  highlighted  EMC  Batch  File.
  725.   F1        MediSoft  Help  Window.
  726.   F2        Prints a utility  EMC Ledger  for the contents of the window.
  727.   F4        Alternates between single or double line  (detail) view mode.
  728.   F6        Changes the current status of the highlighted EMC Batch File.
  729.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit 
  730.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  731. .PA
  732. >CWIN65
  733.                     M A R K   C L A I M    S T A T U S
  734.  
  735.   This  window displays  the claims within  the  selected EMC Batch File.
  736.   This window is  used to change  the  status of  each of the  claims  to
  737.   ACCEPT,  REJECT  or  OK:PAPER.  When a claim is switched to ACCEPT,  no
  738.   additional  processing  occurs.  This  is  because  the  assumption  of
  739.   acceptance is made when the EMC Batch File was transmitted.  It is when
  740.   a claim is switched to  REJECT  that additional processing is required.
  741.   Specifically:  the primary and secondary billing dates are removed, and
  742.   an  adjusting  Insurance  Analysis  record  is  created.
  743.   MediSoft  will  only  process  the rejected claims once all claims have
  744.   been  switched  from  PENDING.
  745. .CO Mark Claim Status
  746.  
  747.   It  is  possible  to  reject  individual  transactions  on  a  claim by
  748.   pressing the [F7] key.  This will pop up the MARK CLAIM ENTRIES window.
  749.   When individual transactions have been rejected,  the claim status will
  750.   be set to PARTREJ (Partial Rejection). If you reject all the line items
  751.   within the MARK CLAIM ENTRIES window,  the claim status  will be set to
  752.   REJECT.  Likewise if you  ACCEPT all  the transactions  within the MARK
  753.   CLAIM  ENTRIES  window,  the  claim  status  will  also  be  ACCEPT.
  754.   Once  ALL  claims within the selected EMC Batch File have been switched
  755.   from PENDING,  the rejected  claims/transactions  will be processed and
  756.   the  status  of  the  EMC  Batch  File  will  be  changed  to  Audit.
  757. .CO Mark Claim Status
  758.  
  759.   Once rejected transactions have been processed, they can be included in
  760.   the next Create Electronic Claims process without having to select  YES
  761.   to the Rebill Transactions field.  If the rejected  transactions reside
  762.   in the  Transaction History  file  you  will  need to enter a  Range of
  763.   Service  Dates  that  will  include  the  history  file.
  764. .CO Mark Claim Status
  765.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  766.   position the highlight.  You may also use  Home,  End,  PgUp and PgDn.
  767.   Other keys that  function within the window are listed at the bottom of
  768.   the  screen.
  769.   Esc       Exit the MARK CLAIM STATUS window WITHOUT processing.
  770.   F1        MediSoft  Help  Window.
  771.   F3        Exit the MARK CLAIM STATUS window AND attempt processing.
  772.   F5        Change the claim status: PENDING, ACCEPT, REJECT, OK:PAPER
  773.   F6        Change status of all claims within the EMC Batch File.
  774.   F7        Access the MARK CLAIM ENTRIES pop up window.
  775. .PA
  776. >TWIN65
  777.                     M A R K   C L A I M    E N T R I E S
  778.  
  779.   This  window  displays  the  transactions  within  the  selected Claim.
  780.   This  window is  used to change  the  status  of  each  transaction  to
  781.   ACCEPT  or  REJECT.  When all the  transactions are set to ACCEPT,  the
  782.   claim will be set to ACCEPT. If all the transactions are set to REJECT,
  783.   the claim will be set to  REJECT.  Only when there is a  combination of
  784.   ACCEPT  and  REJECT  for  the  transactions  will  the  claim be set to
  785.   PARTREJ  (Partial Rejection).
  786. .CO Mark Claim Entries
  787.  
  788.   When a claim is set to PARTREJ,  only those  transactions with a status
  789.   of REJECT will be processed (remove billing dates and enter an adjustment
  790.   into the Insurance Analysis file).
  791.   You will use the  [F5]  key  to  change  the  status of the highlighted
  792.   transaction to either  ACCEPT or  REJECT.  You will use the [F6] key to
  793.   change  the  status  of  all  transactions  on  the  claim.
  794. .CO Mark Claim Entries
  795.  
  796.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  797.   position the highlight.  You may also use  Home,  End,  PgUp and PgDn.
  798.   Other keys that  function within the window are listed at the bottom of
  799.   the  screen.
  800.   Esc       Exit the MARK CLAIM ENTRIES window and save.
  801.   F1        MediSoft  Help  Window.
  802.   F5        Change the transaction status: ACCEPT, REJECT
  803.   F6        Change status of all transactions on the claim.
  804. .PA
  805. *66 Audit Report
  806.                O P T I O N  I N F O R M A T I O N
  807.  
  808.   An  EMC  Batch  File  may  be  "finalized"  one  of  two  ways:
  809.   1.) MediSoft analyzes a  Post Transmission Report immediately following
  810.       a successful transmission.  During this analyzing process, MediSoft
  811.       is able to  determine acceptance and rejection  at the claim level.
  812.   2.) You manually  determine the  acceptance/rejection  for  all  claims
  813.       within  the  EMC  Batch  File.
  814.   Either  method  will  result  in  an  EMC  Batch  File status of Audit.
  815.   This status indicates  that the  EMC Batch File  is finalized,  but now
  816.   requires  the  creation  of  an  audit  trail.
  817. .CO Print Audit/Edit Report
  818.  
  819.   This audit trail will list the  EMC Batch File  information in the same
  820.   format as the  Verification Report.  The Audit/Edit  report  will  also
  821.   include  claim  and  transaction  acceptance/rejection  information.
  822.   Acceptance  and  Rejection  totals  will  be  reported  at the provider
  823.   subtotal  level  and  the  report  total  level.
  824.   The  Insurance  Summary  (if  printed)  will  also  be broken down into
  825.   Acceptance  and  Rejection  totals.
  826.   Upon printing of an Audit/Edit report, the status of the EMC Batch File
  827.   is changed to the system date when the EMC Batch File received a status
  828.   of  Audit.  At  that  point  the  EMC  Batch  File  may  be  purged.
  829. .PA
  830. >6601
  831.  
  832.   Audit Report Type:
  833.   Enter a  1, 2 or 3  to select a  specific type of  Audit Report.
  834.   1: Summary  - Print a single line for each claim.
  835.   2: Standard - Print basic patient and insurance information.
  836.                 Print detailed transaction information.                  
  837.   3: Detailed - Print detailed patient, insurance, facility and referring
  838.                 provider information.                                    
  839.                 Prints detailed transaction information.                 
  840. .PA
  841. >6602
  842.                                                                          
  843.   Print Insurance Summary:  Following each EMC Batch File Audit/Edit 
  844.   Report is the Insurance Type Summary page.  This  optional  document
  845.   summarizes claim amounts by Insurance  Carrier Type:  Commercial/NEIC,
  846.   Medicaid Phys, Medicare/Medicaid,  Medicare, Blue Cross/Blue Shield,
  847.   Blue Cross  Physician, Champus  or  Workmans  Compensation.                                   
  848.   Select  "Y" for yes to  include  this  page  after  each  Audit/Edit  
  849.   Report. Select "N" for no to  exclude  this  page.                                  
  850. .PA
  851. >6603
  852.                                                                          
  853.   Print New Attachments:  During BBS connections it is possible to 
  854.   "attach"  downloaded files to existing EMC Batch Files. It is possible 
  855.   to have more than one download attached to any given EMC Batch File  
  856.   (up to 16).  When you  print the Post Transmission Report, all attached 
  857.   files are  printed and MediSoft stores a last printed indicator. It is 
  858.   possible to attach new downloads to an EMC Batch File between the Post 
  859.   Transmission Report  and  the Audit/Edit  Report.  These  are  
  860.   considered  New  Attachments.  Select "Y" for yes to include new or 
  861.   unprinted EMC Batch File attachments.  Select "N" for no to exclude new 
  862.   or unprinted EMC Batch File attachments. 
  863. .PA
  864. >6604
  865.                                                                          
  866.   Reprint Old Attachments:  Select "Y" for yes to include any Post 
  867.   Transmission Reports  that have already been  printed.  Select "N" for
  868.   no to exclude previously  printed  Post Transmission Reports.
  869. .PA
  870. >XWIN66T
  871.                   T A G   E M C   B A T C H   F I L E S                  
  872.                                                                          
  873.   This window is used to modify the  "selection list"  of EMC Batch Files
  874.   that  will  have  an  Audit/Edit  Report  printed. When an EMC Batch 
  875.   File  is processed  after transmission,  or when the file  is  manually
  876.   completed using the  Mark Claim Status option, the status is set to 
  877.   Audit,  and is tagged and  ready for printing.  So you would not need 
  878.   to modify  the settings in the  TAG column.  It would be more likely 
  879.   that  you  may  need  to  reprint  a  Audit/Edit  Report.  In that 
  880.   event,  this  window  allows you to change the  YES/NO  setting in the 
  881.   TAG column.  By pressing the SPACEBAR you toggle the TAG setting for 
  882.   the  highlighted  EMC Batch File.  By pressing the F5 key, you toggle
  883.   the  TAG  setting  for  ALL  the  EMC  Batch  Files.           
  884. .CO TAG EMC Batch Files
  885.  
  886.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  887.   position the highlight.  You may also use  Home,  End,  PgUp and PgDn.
  888.   Other keys that  function within the window are listed at the bottom of
  889.   the  screen.                                                           
  890.   Esc       Exits the window, and positions the cursor at the last field.
  891.   Enter     Begin the Audit/Edit Report printing process.                
  892.   Space     Change the  TAG  setting for the  highlighted EMC Batch File.
  893.   F1        MediSoft  Help  Window.                         
  894.   F2        Prints a utility  EMC Ledger  for the contents of the window.
  895.   F4        Alternates between single or double line  (detail) view mode.
  896.   F5        Change  the  TAG  setting  for all of the  EMC  Batch  Files.
  897.   F6        Changes the current status of the highlighted EMC Batch File.
  898.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit 
  899.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  900. .PA
  901. *67 Carrier BBS Connection
  902.                O P T I O N  I N F O R M A T I O N                        
  903.                                                                          
  904.   The  Carrier BBS Connection  screen is a  service utility.  Use of this
  905.   portion  within  MediSoft  performs  no  modification  of  any  files. 
  906.   No status' are  updated,  no  transactions  are  modified,  no  billing
  907.   processes occur.  You may use this  screen as often or as little as you
  908.   need.  Its purpose however,  is invaluable.  As mentioned earlier, your
  909.   EMC receivers   may not provide  you  with any  immediate  online  Post
  910.   Transmission Reports  following the  automated  EMC Batch File  upload.
  911.   Thus,  you may need to  acquire claim  acceptance and rejection  reports
  912.   by  some  alternate  means.                                            
  913. .CO Carrier BBS Connection
  914.   Some EMC receivers will mail those reports. Other carriers allow you to
  915.   acquire the reports through a Bulletin Board System (BBS).  Essentially,
  916.   you dial up the EMC receiver,  provide some general information, access
  917.   some menus, then hangup. The "access some menus" aspect includes making
  918.   inquiries into payments,  EOBs, personal mail,  medical bulletins, Post
  919.   Transmission Reports and  Claim Status Reports.  Not necessarily all of
  920.   these  functions  described  will be available.  There may be many more
  921.   features  than  described.  It  is  dependent  upon  the  EMC receiver.
  922. .CO Carrier BBS Connection
  923.   MediSoft provides the means  to get you  connected to an  EMC receivers
  924.   BBS. Not all receivers provide a BBS. MediSoft addresses those that do.
  925.                                                                          
  926.   MediSoft automatically establishes a connection to the BBS, and in many
  927.   cases automatically gets you signed on (logged).  You  may  immediately
  928.   begin accessing the BBS menu options.  You  must  refer  to  the manual
  929.   included  with  your  MediSoft  EMC  Direct  software  for  details  on
  930.   availability  and  usage  of  an  EMC  receivers  BBS.                 
  931. .CO Carrier BBS Connection
  932.   MediSoft provides a generic way for you to access various  BBS systems.
  933.   Included  with your  MediSoft product is a  MediSoft  BBS  Format File.
  934.   Not only will this EMC Format File give you access to the MediSoft BBS,
  935.   but  to  virtually  any  other  BBS  you  desire.  There  are  several 
  936.   limitations:                                                           
  937.   1.) The Bulletin Board must be ANSI-BBS terminal emulation.            
  938.       VT-100, DEC, etc. will not work correctly.                         
  939.   2.) There is no "automatic" signon available, thus your sign-on        
  940.       process must be a user friendly (non coded) sign on.               
  941.   3.) The BBS must be an N-8-1 (No Parity, 8 data bits, 1 stop bit)      
  942.       connection. If it is not (i.e. 7-E-1 for Compuserve) you will be   
  943.       required to modify your connection settings immediately after      
  944.       entering the "Terminal Mode" using the [F10] Utilities key.        
  945. .CO Carrier BBS Connection
  946.                     T H E   M E D I S O F T   B B S                      
  947.                                                                          
  948.   MediSoft BBS specific setup and configuration details can be found 
  949.   in your manual to get you connected for the first time.
  950. .CO Carrier BBS Connection
  951.                 G E N E R I C   B B S   A C C E S S                      
  952.                                                                          
  953.   The following steps will setup a  generic  (user desired)  BBS, and get
  954.   you  connected  for  the  first  time.                                 
  955.   1. Go to the Carrier BBS Connection option of MediSoft.                
  956.   2. Press the [F8] EMC Settings key.                                    
  957.   3. Press the [F6] Search key.                                          
  958.   4. Press the [F8] New key.                                             
  959.   5. Enter the desired BBS for the Insurance Name (i.e. "CompuServe").   
  960.   6. Press the [F3] Save key.                                            
  961.   7. Enter "MBBS" for the Format File ID.                                
  962.   8. Leave Receiver ID, Submitter ID, Password and Contact blank.        
  963. .CO Carrier BBS Connection
  964.   9.  Enter "OPEN" into the Region field. MUST USRE UPPERCASE LETTERS!       
  965.   10. Leave the Mode Indicator field set to "TEST".                      
  966.   11. Enter the appropriate phone number for the BBS. NO PUNCTUATION.    
  967.   12. Use the arrow key to set the Serial Port field to either COM1:,     
  968.       COM2:, COM3: or COM4:; whatever is appropriate for your hardware   
  969.       configuration.                                                     
  970.   13. Use the arrow key to set the Baud Rate field to either 2400, 9600, 
  971.       19200, 38400 or 57,600; whatever is appropriate for your modem.    
  972.       If you have a 14.4k modem you should try 57,600 first. Press       
  973.       [Enter] to accept the displayed Baud rate.                         
  974.   14. Press [Enter] to accept the displayed default "ATDT" for the       
  975.       Modem Dialing PREFIX field.                                        
  976. .CO Carrier BBS Connection
  977.   15. Press [Enter] to accept leave the Modem Dialing SUFFIX field blank.
  978.   16. Leave the Modem Deinitialization field blank.                      
  979.   17. Change the Connection Attempts field to "0".                       
  980.   18. Leave the Receiver Type field set to "Clearing House".             
  981.   19. Leave the BBS Submitter ID and BBS Password fields blank.          
  982.   20. Press the [F3] Save key.                                           
  983.   21. Press the [Esc] key.                                               
  984.   22. Press the [F7] EMC Lookup key.                                     
  985. .CO Carrier BBS Connection
  986.   23. Use the cursor control keys to highlight the desired BBS.          
  987.   24. Press [Enter] to select the highlighted EMC receiver.              
  988.   25. Press [Enter] again to initiate the BBS connection process.        
  989.   26. If the settings you entered for the Serial Port, Baud Rate,        
  990.       Modem Dialing PREFIX and SUFFIX are correct; and the modem is      
  991.       connected to a valid phone line, then MediSoft will successfully   
  992.       dial into the selected BBS !                                       
  993.   27. Refer to your MediSoft manual, or [F1] Help for information on the 
  994.       MediSoft Terminal Emulator.
  995. .PA
  996. >6701
  997.                   F I E L D  I N F O R M A T I O N                       
  998.                                                                          
  999.   Direct Receiver/Insurance Carrier:                                     
  1000.   Enter  the  EMC  receiver  number  for  the  desired  BBS.             
  1001.   If the selected EMC receiver does not offer a BBS an error message will
  1002.   be displayed.  Otherwise,  MediSoft  will  automatically connect to the
  1003.   BBS.  Refer to  your  EMC Direct  reference  manual for any  additional
  1004.   information  regarding  each  EMC  receivers'  BBS.                    
  1005.   Press the  [F6] Search  key for the standard MediSoft Insurance Carrier
  1006.   search window.  Press the [F7] EMC Lookup for a pop up selection window
  1007.   of  established  EMC  receivers. Press [Esc] to return to the sub-menu.
  1008. .PA
  1009. >SPEC6701
  1010.                   T E R M I N A L   E M U L A T O R                      
  1011.                   - You are no longer in MediSoft -                      
  1012.                                                                          
  1013.   You  are  now  in  "Terminal  Mode"  and  MediSoft  is  your  "Shell". 
  1014.   What you are  seeing on the screen  is data that  is coming  across the
  1015.   phone line from the  BBS to which you are  connected.  This information
  1016.   is being converted by your modem,  and then  displayed on  the monitor.
  1017.   Your "job" is to respond to the BBS prompts  (or questions) in order to
  1018.   "navigate" the BBS menu structure,  to reach the  information pertinent
  1019.   to your needs.  You navigate  (or respond) to the BBS prompts by simply
  1020.   entering  the  appropriate  response  to  each  unique  prompt.        
  1021. .CO Terminal Emulator
  1022.   All Bulletin Board Systems do, fundamentally, the  same  things:     
  1023.  
  1024.   1.) Upload (or Send) Data and/or Files                                 
  1025.   2.) Download (or Receive) Data and/or Files                            
  1026.   3.) View Mail/Messages and other Information                           
  1027.   4.) Enter and Direct Mail/Messages and other Information               
  1028.                                                                          
  1029.   The  MENUing  structure and  associated prompts  are merely the vehicle
  1030.   by  which  those  fundamental  functions  are  completed.  Typical to a
  1031.   BBS  environment  is the  "default" response.  This means that many 
  1032.   times,  you need not enter any  information,  just accept the default.  
  1033.   With most BBS,  you will eventually see the following prompt:
  1034. .CO Terminal Emulator
  1035.           Do you want graphics (Enter=yes) ?                             
  1036.                                                                          
  1037.   By simply pressing  [Enter] you would be telling the BBS that YES,  you
  1038.   do want to use graphics.  Another example might be:                    
  1039.                                                                          
  1040.        (2) Enter the filename to download (Enter=none):                  
  1041.                                                                          
  1042.   By just pressing  [Enter]  without supplying a filename,  you have told
  1043.   the  BBS  system that you  DO NOT  want to enter anymore  filenames for
  1044.   downloading,  and  to  continue  with  the  next  logical  step.       
  1045.   In most cases the  BBS  will give you a list of  valid entries that may
  1046.   be  selected.  For  example:                                           
  1047. .CO Terminal Emulator
  1048.         Files List Command (X=Main Menu, G=Goodbye, #=Directory) ?         
  1049.                                                                          
  1050.   In this case,  you could enter an  'X' to return to the  BBS Main Menu.
  1051.   A 'G' would disconnect from the BBS altogether; and a number from the
  1052.   menu will yield a listing of the files available in a selected 
  1053.   Directory. In most cases the letter 'H' or the word 'HELP' will access
  1054.   help information pertinent to the functions available on the selected 
  1055.   BBS.  That explains the "Terminal Mode" concept.                             
  1056. .CO Terminal Emulator
  1057.   The  "Shell"  refers to the fact that you may access MediSoft functions
  1058.   through the use of the  "command keys"  listed across  the  bottom  two
  1059.   lines of this screen.  By selecting [F1] Help, you have made use of one
  1060.   of  these  "command keys".                                             
  1061.   
  1062.   A brief description of each command key:                               
  1063.   [F1] Help                                                              
  1064.      Brings up context sensitive help.  Other functions  have  additional
  1065.      levels  of  specific  help  which  are  activated  by this same key.
  1066. .CO Terminal Emulator
  1067.   [F4] ClearScrn                                                         
  1068.      Clears  all information  currently  displayed  within  the  Terminal
  1069.      Window  and  places  the  cursor  in  the  upper  left  corner.     
  1070.                                                                          
  1071.   [F7] LogScrn                                                           
  1072.      Activates SESSION LOG RECORDING and places the last 1000 characters
  1073.      displayed into the "Log" file. This can also be defined by saying
  1074.      it "dumps" the contents of the screen to a log file, and begins
  1075.      recording the Terminal Mode session.                            
  1076. .CO Terminal Emulator
  1077.   [F8] Rec On/Rec Off                                                    
  1078.      Activates the SESSION LOG RECORDING, but does not retroactively log
  1079.      information currently displayed.  This method of session recording
  1080.      does not "capture the screen", but merely begins recording from that
  1081.      point forward.                                                      
  1082.  
  1083.      If session recording has already been started, this function will
  1084.      stop the session recording and close the "Log" file.        
  1085. .CO Terminal Emulator
  1086.   [F9] Hangup                                                            
  1087.      Terminates the Terminal Mode at that point and returns you to the
  1088.      MediSoft EMC Sub-Menu.  Normally, Terminal Mode will automatically
  1089.      hangup and exit when it senses a loss of the  carrier signal.  This
  1090.      usually takes a few seconds for the modem to  sense and activate the
  1091.      automatic hangup feature.  You may "lockout" the automatic hangup
  1092.      feature,  and force use of the  [F9] Hangup command by pressing the
  1093.      [Alt] [F1]  key  combination.  This is useful if you want to work in
  1094.      the  "Modem Command State" when Carrier Detect is normally "low".
  1095. .CO Terminal Emulator
  1096.   [F10] Utilities                                                        
  1097.      For more  experienced communications users,  this menu allows you to
  1098.      modify settings directly relating to the current session. Any change
  1099.      made from this menu is only  temporary  and  WILL  NOT  affect those
  1100.      default  settings  defined  in  the  Change  EMC  Settings  screen. 
  1101.                                                      
  1102.   [PgUp] Send                                                            
  1103.      Initiate a MediSoft Upload. First step determines the PROTOCOL to be
  1104.      used.  After that,  you specify the file(s)  to be sent  to the BBS.
  1105. .CO Terminal Emulator
  1106.   [PgDn] Receive                                                         
  1107.      Initiate a MediSoft Download.  First step determines the PROTOCOL to
  1108.      be used.  After that,  you may be asked  if you want to  ATTACH  the
  1109.      download to an EMC Batch File.  If not,  you may be asked to specify
  1110.      a destination filename.                                             
  1111. .CO Terminal Emulator
  1112.   COM Settings                                                           
  1113.     In  the lower left corner  of the  screen  are the  current  COM  (or
  1114.     communications)  settings.  The COMx:  number  refers  to the current
  1115.     Serial Port actively selected. The next fields are the Baud Rate, the
  1116.     Word Length,  the Parity and the Stop Bits.  These values are used to
  1117.     describe most BBS connections.  Most common is the 8-N-1, which means
  1118.     eight  (8) data bits,  No parity and one  (1) Stop Bit.  Second  most
  1119.     popular connection is 7-E-1,  or seven (7) data bits, Even parity and
  1120.     one (1) Stop Bit.                                                    
  1121.  
  1122.     NOTE: Users running  DOS  based MediSoft out of  Windows  will notice
  1123.     a Baud Rate of  -1.  MediSoft is unable to report the Baud Rate while
  1124.     running  under  Windows.  THIS  DOES  NOT  AFFECT  PROCESSING !      
  1125. .CO Terminal Emulator
  1126.                       F I L E   T R A N S F E R S                        
  1127.                        Uploading and Downloading                         
  1128.                                                                          
  1129.   Without a doubt,  the most confusing  aspect of modem communications is
  1130.   the  concept of  File Transfer.  Also  known as Uploading,  Downloading
  1131.   and  File Send/Receive.                                                
  1132.   HERE  IS  HOW  YOU  PERFORM  FILE  TRANSFERS:                          
  1133.   First,  you tell the  BBS to either  send or  receive  files.  This  is
  1134.   usually accomplished by selecting either  "U"  for  Upload or  "D"  for
  1135.   Download from the appropriate BBS menu (Menu structure and command keys
  1136.   vary between EMC receiver BBS). BOTTOM  LINE: you tell the BBS you want
  1137.   to  send  or  receive  files.                                          
  1138. .CO Terminal Emulator
  1139.   Second, tell the BBS the file(s) you want to  send/receive.  If you are
  1140.   sending files from your system to the BBS (uploading), you will usually
  1141.   have  to  follow  the  filename  with  a  description.                 
  1142.                                                                          
  1143.   Whatever default  protocol  you have selected  will now  play a part in
  1144.   what happens next.  If your  default protocol  is any of the following:
  1145.   ASCII, XModem/Checksum, Xmodem-CRC, XModem-LRC, XModem-1K, XModem-1K-G 
  1146.   the  BBS  will  begin  trying  to  send/receive  the  defined filename.
  1147.   Otherwise, if  your  default  protocol  is  any  of  the  following:   
  1148.                  YModem-Batch, Ymodem-G, Kermit, ZModem                  
  1149. .CO Terminal Emulator
  1150.   the BBS will ask you to enter the next filename. You will need to leave
  1151.   the  filename  field  blank  and  press  [Enter] to end the "file list"
  1152.   building  mode.  Then  you  will  be  asked  the  following:           
  1153.   (A)bort, (C)ont, (E)dit, (G)oodbye, (L)ist, (P)rotocol, (Enter=cont)   
  1154.                                                                          
  1155.   You may scrap the transfer process,  continue with the next step,  edit
  1156.   your  "file list",  hangup when transfer is complete,  view your  "file
  1157.   list"  or select  a different  protocol.  If you select  (C)  or  press
  1158.   [Enter]  to continue,  the  BBS  will begin trying to  send/receive the
  1159.   defined  filename(s).                                                  
  1160. .CO Terminal Emulator
  1161.   Third, you begin the file transfer process on your "local" end.  If you
  1162.   are sending files to the  BBS  (uploading) you will press the  [PageUp]
  1163.   key.  If you are receiving files from the  BBS  (downloading) you press
  1164.   the [PageDown] key.  If you are downloading and the BBS is using either
  1165.   Kermit or ZModem,  you will not have to press the  [PageDown] key.  The
  1166.   "local"  receive  process  will  be  initiated  automatically !        
  1167. .CO Terminal Emulator
  1168.   Fourth, you must select the protocol. You must select the same protocol
  1169.   that the BBS is using to send/receive. In many cases, the BBS will have
  1170.   the current protocol displayed on the screen  (middle to bottom, left).
  1171.   Using  the  arrow  keys,  highlight  and  select  the  same  protocol. 
  1172.   If you are downloading and the  BBS  is using either  Kermit or Zmodem,
  1173.   the  protocol  will  be  selected  automatically !                     
  1174. .CO Terminal Emulator
  1175.   The  fifth  step  varies  for  uploads  or  downloads.                  
  1176.  
  1177.   If  you  are  UPLOADING:                                               
  1178.   MediSoft  will ask you to specify the file to send to the  BBS.  If the
  1179.   file(s)  are located anywhere but the  MediSoft program directory,  you
  1180.   must  specify  the  FULL DRIVE:\PATH\FILENAME !                        
  1181.   If  you  are  uploading  using  one  of  the  following  protocols:    
  1182.  
  1183.                YModem Batch, YModem-G, Kermit, ZModem                    
  1184.                                                                          
  1185.   You may include standard  DOS wildcard identifiers ( ?, * ) to indicate
  1186.   multiple  (or  batched)  files.                                        
  1187. .CO Terminal Emulator
  1188.   If  you  are  DOWNLOADING:                                             
  1189.   Unless you are downloading using  ZModem,  MediSoft will now ask if you
  1190.   want to ATTACH the first file in the download to an EMC Batch File.  If
  1191.   you enter the letter  "Y"  for  YES,  you will be able to select an EMC
  1192.   Batch File,  to which the file that is being  downloaded will  become a
  1193.   Post Transmission Report !  If you ATTACH,  MediSoft will automatically
  1194.   assign the filename for the downloaded file. If you enter "N" for NO to
  1195.   the ATTACH prompt, MediSoft will not assign the download file to an EMC
  1196.   Batch File.  In that case  you may be asked  to  give  a  "destination"
  1197.   filename.  If  the  protocol  is  one  of  the  following:             
  1198.         ASCII, XModem/Checksum, XModem-CRC, XModem-1k, XModem-1k-G       
  1199. .CO Terminal Emulator
  1200.   you will be prompted to enter the "destination" filename. This filename
  1201.   may also include drive and path specifications.  If the protocol is one
  1202.   of  the  following:                                                    
  1203.                  YModem Batch, YModem-G, Kermit, ZModem                  
  1204.                                                                          
  1205.   you will NOT be prompted for the "destination" filename.  The filenames
  1206.   will  be  assigned  automatically  as  the  file(s)  are  received.    
  1207. .CO Terminal Emulator
  1208.   If you are using the ZModem protocol to download, you do not need to do
  1209.   anything  at  all.  ZModem  downloads  are  fully  automatic !         
  1210.   If you are using the  Kermit  protocol,  you will not need to press the
  1211.   [PageDown] key.  You  will  however,  be  able  to select Y or N to the
  1212.   "ATTACH first file..." prompt.                                         
  1213.                                                                          
  1214.                 YOU ARE NOW TRANSFERRING YOUR FILE(S) !!!                
  1215. .CO Terminal Emulator
  1216.   Notice the  File Transfer  "popup" window.  Make a  special note of the
  1217.   "Retries" and "Bytes" counters. If the Retries count up - and the Bytes
  1218.   do not;  then you have a problem.  Or if an  error box  appears  on the
  1219.   screen,  the  File Transfer has failed.  Here are some reasons why file
  1220.   transfers  fail:
  1221.                                                          
  1222.   1.) The  BBS  and  MediSoft  are  not  using  the  same  PROTOCOL.     
  1223.   2.) The  filename  you entered to upload is invalid  (missing, typo...)
  1224.   3.) The download  file already exists and is attributed as  READ ONLY !
  1225.   4.) You  have  a  "noisy"  connection.                                 
  1226. .CO Terminal Emulator
  1227.   If you do not get an error, then your transfer was successful. Most BBS
  1228.   give  a  message  indicating  success.                                 
  1229.   NOTE: All BBS vary in design and implementation.  But one common thread
  1230.   exists:  You must always get the  BBS into it's upload/download waiting
  1231.   state before you initiate the  MediSoft  (local end)  upload/download !
  1232. .PA
  1233. >SPEC670-1
  1234.                                                                          
  1235.   ASGENERALERROR: -1                                                     
  1236.   This is a general modem failure error. This error usually indicates a  
  1237.   hardware failure. You should try another modem, or other communications
  1238.   software to assist in diagnosing the problem.                          
  1239. .PA
  1240. >SPEC670-2
  1241.                                                                          
  1242.   ASINVPORT: -2                                                          
  1243.   You have selected a Serial Port that is not recognized by MediSoft.    
  1244.   Use the [F10] Utilities option to select another Serial Port.          
  1245. .PA
  1246. >SPEC670-3
  1247.                                                                          
  1248.   ASINUSE: -3                                                            
  1249.   The Serial Port you have specified is currently in use by another      
  1250.   application. MediSoft cannot access a serial port that is already open.
  1251.   You may need to close all applications and restart the computer.       
  1252. .PA
  1253. >SPEC670-4
  1254.                                                                          
  1255.   ASINVBUFSIZE: -4                                                       
  1256.   MediSoft could not reserve a block of memory for the specified Serial  
  1257.   Port. You may need to close all applications and restart the computer. 
  1258. .PA
  1259. >SPEC670-5
  1260.                                                                          
  1261.   ASNOMEMORY: -5                                                         
  1262.   MediSoft has run out of available working memory. You may need to close
  1263.   all applications and restart the computer.                             
  1264. .PA
  1265. >SPEC670-6
  1266.                                                                          
  1267.   ASNOTSETUP: -6                                                         
  1268.   The currently defined Serial Port was never successfully opened.       
  1269.   Use the [F10] Utilities menu option to reselect the required Serial    
  1270.   Port.                                                                  
  1271. .PA
  1272. >SPEC670-7
  1273.                                                                          
  1274.   ASINVPAR: -7                                                           
  1275.   One of the selected menu options was invalid for your modem. Use the   
  1276.   [F10] Utilities menu to reselect the desired menu options.             
  1277. .PA
  1278. >SPEC670-8
  1279.                                                                          
  1280.   ASBUFREMPTY: -8                                                        
  1281.   The Modem Receive Buffer is empty and is unable to transfer the        
  1282.   requested number of bytes. You should try this command again when the  
  1283.   Modem Receive Buffer is not empty.                                     
  1284. .PA
  1285. >SPEC670-9
  1286.                                                                          
  1287.   ASBUFRFULL: -9                                                         
  1288.   The Modem Transmit Buffer is empty and is unable to transfer the       
  1289.   requested number of bytes. You should try this command again when the  
  1290.   Modem Transmit Buffer is not empty.                                    
  1291. .PA
  1292. >SPEC670-10
  1293.                                                                          
  1294.   ASTIMEOUT: -10                                                         
  1295.   A timeout has occured. An allotted time specification has been 
  1296.   exceeded.
  1297. .PA
  1298. >SPEC670-11
  1299.                                                                          
  1300.   ASNOCTS: -11                                                           
  1301.   Clear To Send (CTS) was expected but not asserted. Either try the      
  1302.   command again, or use the [F10] Utilities menu to disable CTS/RTS.     
  1303. .PA
  1304. >SPEC670-12
  1305.                                                                          
  1306.   ASNOCD: -12                                                            
  1307.   Carrier Detect (CD) was expected but not asserted. You may not issue   
  1308.   this command without a CD signal.                                      
  1309. .PA
  1310. >SPEC670-13
  1311.                                                                          
  1312.   ASNODSR: -13                                                           
  1313.   Data Send Ready (DSR) was expected but not asserted. Try again.        
  1314. .PA
  1315. >SPEC670-14
  1316.                                                                          
  1317.   ASNO8250: -14                                                          
  1318.   The Serial Port selected does not report the 8250 family UART (modem). 
  1319.   You have possibly selected the port to which the mouse is connected, or
  1320.   some other serial peripheral.                                          
  1321. .PA
  1322. >SPEC670-16
  1323.                                                                          
  1324.   ASUSERABORT: -16                                                       
  1325.   You have pressed the [Esc] key during a file transfer, or during a     
  1326.   Hayes Modem command. If you did not press the [Esc] key, then there is 
  1327.   probably line noise interference.                                      
  1328. .PA
  1329. >SPEC670-19
  1330.                                                                          
  1331.   ASNOWIDERX: -19                                                        
  1332.   No WideTrack receive available on this Serial Port.                    
  1333.   MediSoft cannot successfully WideTrack receive modes and should not be
  1334.   used.                                                                  
  1335. .PA
  1336. >SPEC670-20
  1337.                                                                          
  1338.   ASCONFLICT: -20                                                        
  1339.   There was an attempt to open multiple ports on shared interrupt board  
  1340.   using different interrupt lines and a conflict occured.                
  1341. .PA
  1342. >SPEC670-22
  1343.                                                                          
  1344.   ASNOHAYESOK: -22                                                       
  1345.   An "OK" response was expected from the modem but not received.         
  1346.   You may have a problem with the modem.                                 
  1347. .PA
  1348. >SPEC670-23
  1349.                                                                          
  1350.   ASNOHAYESRESPONSE: -23                                                 
  1351.   A function used by MediSoft did not receive the expected response.     
  1352.   You may need to exit the terminal mode and restart MediSoft.           
  1353. .PA
  1354. >SPEC670-25
  1355.                                                                          
  1356.   ASILLEGALBAUDRATE: -25                                                 
  1357.   The selected Baud Rate is invalid for this modem.                      
  1358.   Use the [F10] Utilities menu option to select a different Baud Rate.   
  1359. .PA
  1360. >SPEC670-26
  1361.                                                                          
  1362.   ASILLEGALPARITY: -26                                                   
  1363.   The selected Parity is not valid for this modem.                       
  1364.   Use the [F10] Utilities menu option to select a different Parity.      
  1365. .PA
  1366. >SPEC670-27
  1367.                                                                          
  1368.   ASILLEGALWORDLENGTH: -27                                               
  1369.   The selected Word Length is not valid for this modem.                  
  1370.   Use the [F10] Utilities menu option to select a different Word Length. 
  1371. .PA
  1372. >SPEC670-28
  1373.                                                                          
  1374.   ASILLEGALSTOPBITS: -28                                                 
  1375.   The selected Stop Bits are not valid for this modem.                   
  1376.   Use the [F10] Utilities menu option to select a different Stop Bits    
  1377.   setting.                                                               
  1378. .PA
  1379. >SPEC670-29
  1380.                                                                          
  1381.   ASNOCOPYRIGHTNOTICE: -29                                               
  1382.   Your MediSoft executable code is corrupt.                              
  1383.   Reinstall MediSoft.                                                    
  1384. .PA
  1385. >SPEC670-31
  1386.                                                                          
  1387.   ASOVERFLOW: -31                                                        
  1388.   The Transmit or Receive Modem Buffers have overflowed.                 
  1389.   Data has been lost. You should disconnect and reconnect.               
  1390.   Or try the file transfer again.                                        
  1391. .PA
  1392. >SPEC670-36
  1393.                                                                          
  1394.   ASHANDSHAKEBLOCK: -36                                                  
  1395.   The selected Handshaking option is blocking polled modem functions.    
  1396.   Use [F10] Utilities to disable all handshaking.                        
  1397. .PA
  1398. >SPEC670-39
  1399.                                                                          
  1400.   ASIRQINUSE: -39                                                        
  1401.   MediSoft could not open the specified Serial Port because the IRQ is   
  1402.   already in use. Exit the terminal mode and restart MediSoft.           
  1403. .PA
  1404. >SPEC670-601
  1405.                                                                          
  1406.   XFER_RETURN_CANT_GET_BUFFER: -601                                      
  1407.   MediSoft could not allocate memory for the file transfer to occur.     
  1408.   You must free up more memory - restart MediSoft and try again.         
  1409. .PA
  1410. >SPEC670-602
  1411.                                                                          
  1412.   XFER_RETURN_CANT_OPEN_FILE: -602                                       
  1413.   The specified file could not be opened.                               
  1414.   The destination file may be read only, or the destination disk may be  
  1415.   write protected. If you are uploading, the filename specified is       
  1416.   missing or invalid.                                                    
  1417. .PA
  1418. >SPEC670-603
  1419.                                                                          
  1420.   XFER_RETURN_CANT_SEND_NAK: -603                                        
  1421.   The file receiver never sent the NAK character or packet.              
  1422.   Try using a different protocol, or just try again.                     
  1423.   Make sure the BBS and your local end are trying to send and receive    
  1424.   in proper coordination.                                                
  1425. .PA
  1426. >SPEC670-604
  1427.                                                                          
  1428.   XFER_RETURN_CANT_SEND_ACK: -604                                        
  1429.   The file receiver never sent the ACK character or packet.              
  1430.   Try using a different protocol, or just try again.                     
  1431.   Make sure the BBS and your local end are trying to send and receive    
  1432.   in proper coordination.                                                
  1433. .PA
  1434. >SPEC670-605
  1435.                                                                          
  1436.   XFER_RETURN_KEYBOARD_ABORT: -605                                       
  1437.   MediSoft reported that the user (local end) pressed the abort key to   
  1438.   stop the file transfer.                                                
  1439. .PA
  1440. >SPEC670-606
  1441.                                                                          
  1442.   XFER_RETURN_REMOTE_ABORT: -606                                         
  1443.   MediSoft reported that the BBS (remote end) pressed the abort key to   
  1444.   stop the file transfer. This may also be caused by line interference.  
  1445. .PA
  1446. >SPEC670-607
  1447.                                                                          
  1448.   XFER_RETURN_FILE_ERROR: -607                                           
  1449.   A File I/O error has occured during a read/write operation on the      
  1450.   current file being transferred.                                        
  1451. .PA
  1452. >SPEC670-608
  1453.                                                                          
  1454.   XFER_RETURN_PACKET_TIMEOUT: -608                                       
  1455.   Timeout waiting for the first character in the packet.                 
  1456.   Try using a different protocol, or just try again.                     
  1457.   Make sure the BBS and your local end are trying to send and receive    
  1458.   in proper coordination.                                                
  1459. .PA
  1460. >SPEC670-609
  1461.                                                                          
  1462.   XFER_RETURN_BAD_PACKET_SIZE: -609                                      
  1463.   Got an invalid packet size.                                            
  1464.   Try using a different protocol, or just try again.                     
  1465.   Make sure the BBS and your local end are trying to send and receive    
  1466.   in proper coordination.                                                
  1467. .PA
  1468. >SPEC670-610
  1469.                                                                          
  1470.   XFER_RETURN_TOO_MANY_ERRORS: -610                                      
  1471.   Exceeded (non-fatal) protocol error limit.                             
  1472.   This may be caused by excessive line interference.                     
  1473.   Try using a different protocol, or just try again.                     
  1474.   Make sure the BBS and your local end are trying to send and receive    
  1475.   in proper coordination.                                                
  1476. .PA
  1477. >SPEC670-611
  1478.                                                                          
  1479.   XFER_RETURN_LOGIC_ERROR: -611                                          
  1480.   Unknown error has occured                                              
  1481.   Try using a different protocol, or just try again.                     
  1482.   Make sure the BBS and your local end are trying to send and receive    
  1483.   in proper coordination.                                                
  1484. .PA
  1485. >SPEC670-612
  1486.                                                                          
  1487.   XFER_RETURN_CAT_PUT_BUFFER: -612                                       
  1488.   Buffer full attempting to transmit data/packet.                        
  1489.   Try using a different protocol, or just try again.                     
  1490.   Make sure the BBS and your local end are trying to send and receive    
  1491.   in proper coordination.                                                
  1492. .PA
  1493. >SPEC670-613
  1494.                                                                          
  1495.   XFER_RETURN_CANT_PUT_BUFFER: -613                                      
  1496.   The file sender failed to issue an EOT character or packet.            
  1497.   Try using a different protocol, or just try again.                     
  1498.   Make sure the BBS and your local end are trying to send and receive    
  1499.   in proper coordination.                                                
  1500. .PA
  1501. >SPEC670-614
  1502.                                                                          
  1503.   XFER_RETURN_PROTOCOL_ERROR: -614                                       
  1504.   The BBS (remote end) is not using the select protocol correctly.       
  1505.   Try using a different protocol, or just try again.                     
  1506.   Make sure the BBS and your local end are trying to send and receive    
  1507.   in proper coordination.                                                
  1508. .PA
  1509. >SPEC670-615
  1510.                                                                          
  1511.   XFER_RETURN_CANT_PUT_CHAR: -615                                        
  1512.   MediSoft could not send a necessary character.                         
  1513.   Try using a different protocol, or just try again.                     
  1514.   This could indicate hardware failure.                                  
  1515. .PA
  1516. >SPEC670-616
  1517.                                                                          
  1518.   XFER_RETURN_CANT_GET_CHAR: -616                                        
  1519.   MediSoft could not receive a necessary character.                      
  1520.   Try using a different protocol, or just try again.                     
  1521.   This could indicate hardware failure.                                  
  1522. .PA
  1523. >SPEC670-617
  1524.                                                                          
  1525.   XFER_RETURN_ASCII_TIMEOUT: -617                                        
  1526.   ASCII file capture, 10 second dead timeout.                            
  1527.   This may not mean there was an error - just that the other end stop    
  1528.   sending data for a period of 10 seconds.                               
  1529. .PA
  1530. >SPEC670-618
  1531.                                                                          
  1532.   XFER_RETURN_LOST_CARRIER: -618                                         
  1533.   Lost carrier during transfer.                                          
  1534.   You must reconnect and try again.                                      
  1535.   This can be caused by line interference, call waiting or the other end 
  1536.   simply hung up.                                                        
  1537. .PA
  1538. >SPEC670-619
  1539.                                                                          
  1540.   XFER_RETURN_NO_FILES: -619                                             
  1541.   No files were found to be sent.                                        
  1542.   Check the filenames you want to send and try again.                    
  1543. .PA
  1544. >SPEC67020
  1545.                                                                          
  1546.   Use the  cursor control  keys to position the  highlight on the desired
  1547.   communication  parameter  and press the [Enter] key.  You can also type
  1548.   the  number  to the left of the  menu option.  Press the  [Esc]  key to
  1549.   return  to  the  Terminal  Mode.                                       
  1550.   Serial Port: Modify the current Serial or COM port setting.            
  1551.                WARNING: Do not change the COM port while "ONLINE".       
  1552.   Baud Rate:   Change the modem speed of the current connection.         
  1553.   Word Length: Change the number of Data Bits for each data byte.        
  1554.   Parity:      Change the type of data byte parity control.              
  1555.   Stop Bits:   Change the number of Stop Bits for each data byte.        
  1556.   Handshaking: Change the methods of communications flow control.        
  1557. .PA
  1558. >SPEC67021
  1559.                                                                          
  1560.   Select the  Serial Port  to be  used for  further communications during
  1561.   this  Terminal  Mode  session.                                         
  1562.   NOTE:  If  you  are  online,  your  current session will be lost if you
  1563.   change  the  current  serial  port.                                    
  1564. .PA
  1565. >SPEC67022
  1566.                                                                          
  1567.   Select  the  desired  Baud Rate  for  the  current  session.           
  1568.   If  you are not currently online, the selected  Baud Rate  will be used
  1569.   during  your  next  connection  within  this  Terminal  Mode  session. 
  1570.   If you are using a  14.4k  Baud Modem,  or greater;  try the  57,600bps
  1571.   setting  first,  and  work  your  way  backwards  to  19,200bps.       
  1572. .PA
  1573. >SPEC67023
  1574.                                                                          
  1575.   Select the desired number of bits to use for data within each data byte
  1576.   transmitted.  Most common are  8  and  7.  You will usually use  8 when
  1577.   connecting with a  PC  based  system.  Mainframes  and  Compuserve will
  1578.   usually  require  7.                                                   
  1579. .PA
  1580. >SPEC67024
  1581.                                                                          
  1582.   Select  the  desired  method  for  parity  error  correction.          
  1583.   NOTE:  If the word length is set to 8, you must set the Parity to NONE.
  1584.   Most  common  is  No  Parity  when  Data  Bits  are  8.  Mainframes and
  1585.   Compuserve  will  usually  require  EVEN  parity.                      
  1586. .PA
  1587. >SPEC67025
  1588.                                                                          
  1589.   Select  the  desired  number  of  bits  to  use as Stop Bit indicators.
  1590. .PA
  1591. >SPEC67026
  1592.                                                                          
  1593.   Select  the  desired  method  of  communications  "flow control".      
  1594.   None:      No hardware or software controls in place to restrict data  
  1595.              traffic flow.                                               
  1596.   XON/XOFF:  Software level flow control that is used when no MNP is     
  1597.              available between the local and remote users.               
  1598.   RTS/CTS:   Hardware level flow control that is used when MNP is        
  1599.              available, but just not activated.                          
  1600.   Both:      Initiate both XON/XOFF and RTS/CTS flow controls.           
  1601. .PA
  1602. >SPEC67027
  1603.                                                                          
  1604.   Select the desired file transfer protocol method.                      
  1605.   Be sure you select the same protocol that is being used by the BBS     
  1606.   (remote end).                                                          
  1607.   Xmodem/Checksum: 128 byte data blocks followed by 1 checksum character.
  1608.                    Good for small files, bad connections, slow modems.   
  1609.   Xmodem/CRC:      128 byte data blocks followed by 2 CRC calculation    
  1610.                    characters. Good for small files, bad connections and 
  1611.                    slow modems when sending binary files (.EXEs & .ZIPs).
  1612.   Xmodem/LRC:      320 byte data blocks followed by 1 checksum character.
  1613.                    Only for sending to Texas Health Information Network. 
  1614. .CO Protocol Selection
  1615.   Xmodem-1k:       1024 byte data blocks followed by a CRC calculation.  
  1616.                    Good for single files on slower modems.               
  1617.   Xmodem-1k-g:     Same as Xmodem-1k with no wait for CRC Acknowledgement
  1618.                    from receiving end. If receiving end reports an error,
  1619.                    the whole transfer aborts.                            
  1620.                    Good only in very special circumstances.              
  1621.   ASCII:           Straight data feed across the modem with no error    
  1622.                    sensing capabilities.                                 
  1623.                    Good only in very special circumstances.              
  1624. .CO Protocol Selection
  1625.   Ymodem Batch:    1024 byte blocks with CRC calculation. Able to        
  1626.                    transfer multiple files in succession. Good for       
  1627.                    multiple and/or binary files. Works like a multi-file 
  1628.                    Xmodem-1k.                                            
  1629.   Ymodem-g:        Same as Ymodem Batch, with the no wait characteristics
  1630.                    of Xmodem-1k-g. Good only very special circumstances. 
  1631.   Zmodem:          High speed, multiple file transfer protocol with error
  1632.                    correcting and crash recovery. This protocol is the   
  1633.                    best in almost every situation, except:               
  1634.                    slow modems during a bad connection.                  
  1635. .PA
  1636. >SPEC67030
  1637.                                                                          
  1638.   Enter the filename to upload. If you are specifying a file that resides
  1639.   in a directory  other than the  MediSoft  program  directory,  you must
  1640.   specify the full  DRIVE:\PATH\FILENAME.EXT.  If  you are  sending using
  1641.   one  of  the  following  protocols:                                    
  1642.                  Ymodem Batch, Ymodem-g, Kermit, Zmodem                  
  1643.                                                                          
  1644.   you  may  use  valid  DOS  wildcards  to  include  multiple  files.    
  1645.   (i.e. FILES*.*, MA??*.TXT, etc.)                                       
  1646.                                                                          
  1647.   Press  [Esc]  to  abandon  the  file  upload  process.                 
  1648. .PA
  1649. >SPEC67031
  1650.                                                                          
  1651.   Enter  the  filename  to  download.  You  may  specify  the  full      
  1652.   DRIVE:\PATH\FILENAME.EXT  if you want the destination file to reside in
  1653.   a directory  other  than  the  MediSoft  program  directory.          
  1654.   You may not use DOS wildcard characters.  The filename entered here 
  1655.   must be  a  valid  singular  filename.                                      
  1656.                                                                          
  1657.   Press  [Esc]  to  abandon  the  file  download  process.               
  1658. .PA
  1659. >SPEC6704
  1660.        A T T A C H   P O S T   T R A N S M I S S I O N   R E P O R T     
  1661.                                                                          
  1662.   Select a transmitted  EMC Batch File  to which  MediSoft can attach the
  1663.   file to be downloaded.  Once  selected,  MediSoft  will  determine  the
  1664.   appropriate  DOS Filename  for the  download  file.  You may  print the
  1665.   resulting  attachment  using  the Print Post Transmission Report option
  1666.   of MediSoft,  or you can print the  report from the  Print Audit Report
  1667.   option.  To  abandon  the  file  attachment,  press  the  [Esc]  key.  
  1668. .PA
  1669. >SPEC6705
  1670.                                                                          
  1671.   The system is asking if you want to manually name the download file(s),
  1672.   or you may have MediSoft name the download file(s) by "attaching" to an
  1673.   existing  EMC Batch File that has been  previously transmitted.  If the
  1674.   file(s)  you  are  downloading  Claim Status  Reports  or  Transmission
  1675.   Acknowledgment Reports from your EMC receiver, you may be in a position
  1676.   to have  MediSoft assign the downloaded file(s) to a specific EMC Batch
  1677.   File.  This  is  referred  to  as  ATTACHing.  Whether  or  not this is
  1678.   recommended will depend upon the EMC receiver. Refer to your EMC Direct
  1679.   Manual for specifications.  If  you  are not downloading EMC Batch File
  1680.   related  information,  just  select  "N"  for  No  to  this  prompt.   
  1681. *68 EMC File Utilities
  1682.                 O P T I O N  I N F O R M A T I O N                       
  1683.                                                                          
  1684.   After creating,  printing, transmitting and marking claims for a period
  1685.   of time,  you will find that your EMC Batch File list is growing out of
  1686.   control. It is time to remove some of the older, billed EMC Batch Files
  1687.   from  the  system.                                                     
  1688.   MediSoft allows you to delete EMC Batch Files from your system, freeing
  1689.   up hard disk space  and  making the  EMC Batch File  selection  windows
  1690.   easier to navigate.  You should  define a  deletion schedule  that best
  1691.   suites  your  own  needs.                                              
  1692.  
  1693. .CO Option Information
  1694.                                                                          
  1695.   This  schedule  should  be  dependent  upon:                           
  1696.   A) How much disk space you have available,  or want to keep available. 
  1697.   B) How frequently you create EMC Batch Files.                          
  1698.   C) How frequently you mark accepted and rejected claims.              
  1699.   D) How long you want to retain billed EMC Batch Files for audit trail  
  1700.      reporting purposes.                                                 
  1701.                                                                          
  1702.   REMEMBER: If you consistently backup your data, you will always have an
  1703.   audit trail.                                                           
  1704.  
  1705. .CO Option Information
  1706.                                                                          
  1707.   Medisoft also allows you to rebuild files and file indexes.  Due to the
  1708.   nature of  MediSoft,  it is  not  effective to  offer a menu for you to
  1709.   select which files you want to rebuild,  since the files vary depending
  1710.   upon  the  results  of  the  Create  Electronic  Claims  option.       
  1711.   MediSoft  instead,  combines  the  Delete and  Index Rebuild functions.
  1712.   You may rebuild  file indexes without deleting,  but  you  will  always
  1713.   rebuild indexes after purging.  This approach helps minimize the amount
  1714.   of  disk space required by  MediSoft.  From  within the  EMC Batch File
  1715.   selection window,  you may select to rebuild the EMC Batch Control File
  1716.   and the EMC Settings File. The EMC Batch Control File contains a record
  1717.   for each  EMC Batch File created using Create Electronic Claims option.
  1718. .CO Option Information
  1719.  
  1720.   The EMC Settings file contains a record for each  EMC Receiver setup in
  1721.   the EMC Receiver Settings option.  Both files are automatically rebuilt
  1722.   each  time  you  exit  the  EMC  File  Utilities  option.              
  1723.   You  may  rebuild  the index  for individual  EMC Batch File,  and it's
  1724.   associated EMC Direct Format File by pressing  [Enter].  When you press
  1725.   [Enter]  the highlighted  EMC Batch File's  control  file  is reindexed
  1726.   along  with  the  EMC  Format  File  assigned  to  the  EMC  Receiver. 
  1727.   You may delete an  EMC Batch File  from the  system by  pressing [F10].
  1728.   When you press  [F10],  the  system  will pop up a  general information
  1729.   window,  displaying information  regarding the selected EMC Batch File.
  1730. .CO Option Information
  1731.  
  1732.   You will be prompted to verify the delete selection.  If you verify the
  1733.   delete selection,  the  EMC Batch File  control  record will be deleted
  1734.   from the  EMC Claims Batch Control File,  and all  files with  the same
  1735.   base  EMC filename  will be removed  from the  EMC subdirectory located
  1736.   just  below  your  MediSoft  Data  directory.                          
  1737. .CO Option Information
  1738. >XWIN68
  1739.                    E M C   F I L E   U T I L I T I E S                   
  1740.                                                                          
  1741.   This window is used to view and select  EMC Batch Files  for performing
  1742.   one  of  the  following  file  maintenance  utilities:                 
  1743.   Index Recreation                                                       
  1744.      Rebuild indexes for the  EMC Batch Control File  and the  EMC Direct
  1745.      Format  File  associated  with  the  EMC  Batch  File.              
  1746.   Delete                                                                 
  1747.      Delete the EMC Batch File from the system. This will include the EMC
  1748.      transmission  file,  control  file,  control  file  index  and  any 
  1749.      attachments associated with the EMC Batch File.  It will also delete
  1750.      the  EMC  Batch  File  reference  from  this  window.               
  1751. .CO EMC File Utilities
  1752.                                                                          
  1753.   Regardless of how many  EMC Batch Files  you  delete,  or  indexes  you
  1754.   rebuild,  upon exiting this option, MediSoft will reindex the EMC Batch
  1755.   Control File,  and EMC Receiver Settings file,  and purge  all  deleted
  1756.   records.  The  EMC Batch Control File  contains  a  record for each EMC
  1757.   Batch File  that  is recreated  within  the  Create  Electronic  Claims
  1758.   option.  The EMC Batch Control File is used to create this window,  and
  1759.   other EMC selection windows.  The EMC Receiver Settings file contains a
  1760.   record  for  each  EMC receiver  defined  in the  EMC Receiver Settings
  1761.   option.                                                                
  1762. .CO EMC File Utilities
  1763.                                                                          
  1764.   While  you  are  in  the  scrolling  window,  use  the  arrow  keys  to
  1765.   position the highlight.  You may also use  Home,  End,  PgUp and PgDn.
  1766.   Other keys that  function within the window are listed at the bottom of
  1767.   the  screen.                                                           
  1768.   Esc       Exits the window, and positions the cursor at the last field.
  1769.   Enter     Reindex the EMC Batch Control and associated Format Files.   
  1770.   F1        MediSoft  Help  Window.                         
  1771.   F2        Prints a utility  EMC Ledger  for the contents of the window.
  1772.   F4        Alternates between single or double line  (detail) view mode.
  1773.   F6        Changes the current status of the highlighted EMC Batch File.
  1774.             STATUS: Verify, Rejected, Billed, Audit, Mark, Transmit 
  1775.   F9        Edit the Comment field  for the  highlighted  EMC Batch File.
  1776.   F10       Delete the select EMC Batch File and all associations.       
  1777. *69 EMC Settings
  1778.              O P T I O N  I N F O R M A T I O N                          
  1779.                                                                          
  1780.   This screen allows you to establish vital information regarding each of
  1781.   the  receivers  to  which  you  will  be  submitting electronic claims.
  1782.   By merely saving a record for an insurance company on this screen,  you
  1783.   subsequently  define them as being a  direct receiver.  From that point
  1784.   on, any time you use the  Create Electronic Claims option,  all patient
  1785.   records  with a  primary insurance company  different  from  the Direct
  1786.   Receiver/Insurance Carrier will be skipped.                            
  1787. .CO EMC Settings
  1788.   The  system  assumes  that  if  the  patients  insurance  company  has 
  1789.   EMC Settings  defined,  then you will  be  filing  directly  with  that
  1790.   receiver, and the patients transactions are to be skipped unless filing
  1791.   directly to that receiver.  So, unless you will be  sending  electronic
  1792.   claims  files  via  modem  directly  to  the  insurance  carrier:      
  1793.     DO NOT DEFINE EMC SETTINGS FOR THE INSURANCE COMPANY ON THIS SCREEN  
  1794.                                                                          
  1795.                 ** This screen is only for your **                       
  1796.                         Direct Receivers                                 
  1797.                               and                                        
  1798.                          Clearing Houses                                 
  1799. .CO EMC Receiver Settings
  1800.                                                                          
  1801.   Some fields on this screen will require  knowledge of how your hardware
  1802.   is set up.  Some will require knowledge of the type of receiver you are
  1803.   defining,  and the rest will require you contact the receiver directly.
  1804.   Please  refer  to  your  MediSoft  Claims Direct  manual for details on
  1805.   supplying information for some of these fields.                        
  1806. .CO EMC Receiver Settings
  1807. >6901
  1808.                    F I E L D   I N F O R M A T I O N                     
  1809.                                                                          
  1810.   Direct Receiver/Insurance Carrier:  Enter the insurance carrier number 
  1811.   for an EMC Receiver. If the receiver is a clearing house,  enter  the  
  1812.   insurance  number  assigned  when the "dummy"  insurance carrier  was 
  1813.   setup within the  Insurance Information option. If the receiver is 
  1814.   Equifax EDI Services, leave this field blank or enter '0000'. When 
  1815.   establishing a Clearing House other than Equifax, remember that the 
  1816.   Insurance Company record is a  "dummy" record, and is for reference 
  1817.   purposes only.                                           
  1818. .CO Direct Receiver/Insurance Carrier
  1819.   You should  NEVER assign a Clearing House number to a Patients Primary,
  1820.   Secondary or Tertiary Insurance Number.  If you do not  know the number
  1821.   for an existing EMC receiver, you may press the  [F7]EMC Lookup  key to
  1822.   access a pop up window of all previously defined EMC Receivers.        
  1823.   If you want to lookup an  insurance company for the purpose of defining
  1824.   EMC Receiver Settings,  you may press the  [F6]Search key to access the
  1825.   standard  MediSoft  Insurance  Company  Search  Window.                
  1826. .PA
  1827. >6902
  1828.                                                                          
  1829.   Format File ID: This field links directly to a "Format File" which was 
  1830.   loaded onto your hard drive.  Refer to your MediSoft Direct EMC manual 
  1831.   for the appropriate code to enter into this field.  This format file 
  1832.   contains instructions which the  Create Electronic Claims  option uses 
  1833.   to build an EMC Batch File for transmission. All carriers have 
  1834.   different instructions for how to submit claims directly.  When you 
  1835.   loaded MediSoft onto your system, you also loaded the  format files for  
  1836.   EMC services.  These  formats  are  named  ETS6  and  ENV1.
  1837.   Descriptive information for these files is located on the upper left
  1838.   corner of the screen.                           
  1839. .CO Format File ID
  1840.                                                                          
  1841.   AUTO MARK:  This  Format  Fact  indicates  that  after  a  successful  
  1842.   transmission,  the  EMC Batch File  will automatically be processed for
  1843.   claim acceptance and rejection  based upon an immediate attachment made
  1844.   available by the EMC Receiver (i.e. ETS6, ETS5).  If this Format Fact 
  1845.   is not displayed, then users must perform claim status determination 
  1846.   using the  Mark  Claim  Status  option.                                      
  1847.   BBS AVAILABLE: This Format Fact indicates support of the BBS Connection
  1848.   option.  You will need to refer to the  EMC Direct  manual for specific
  1849.   details on why,  how and when to access the receivers BBS system(s). If
  1850.   this Format Fact is not displayed,  then  you  may  not select this EMC
  1851.   Receiver  in  the  BBS  Connection  option.                            
  1852. .CO Format File ID
  1853.                          M O D E M   T E S T                             
  1854.   With this version of  MediSoft  you now  have the  ability to test your
  1855.   hardware  configuration  without  having  to  go to  either  Transmit   
  1856.   Electronic Claims or BBS Connection.  By pressing  [F9]Modem Test,  the
  1857.   system  will  open  the defined Serial Port at the specified Baud Rate.
  1858.   It  will  test  the modem for Hayes Modem compatibility,  and then test
  1859.   the  specified  Modem  Dialing Prefix,  Phone Number and Suffix for any
  1860.   ERROR result codes.  A  pop  up  Modem  Configuration  Window  displays
  1861.   each step and the results of  each  testing  step.  If any of the tests
  1862.   fail,  a General Error  description  and  Error ID number is displayed.
  1863. .PA
  1864. >6903
  1865.                                                                          
  1866.   Receiver ID:  Refer to the  MediSoft  Field  Requirements  section  
  1867.   of the EMC manual for appropriate  Format  File  entry  instructions.                        
  1868. .PA
  1869. >6904
  1870.                                                                          
  1871.   Submitter ID:  Refer to the MediSoft Field Requirements section of 
  1872.   the EMC  manual for appropriate  Format  File  entry  instructions.                        
  1873. .PA
  1874. >6905
  1875.                                                                          
  1876.   Password:  Refer to the  MediSoft  Field  Requirements  section  of  
  1877.   the EMC  manual  for appropriate  Format  File  entry  instructions.                        
  1878. .PA
  1879. >6906
  1880.                                                                          
  1881.   Region: Refer to the  MediSoft  Field  Requirements  section  of  
  1882.   the  EMC manual  for appropriate  Format  File  entry  instructions.                        
  1883. .PA
  1884. >6907
  1885.                                                                          
  1886.   Contact:  As the name implies,  this field  would most  likely  be  
  1887.   used to store Contact information for your office.  However, you should 
  1888.   refer to the the MediSoft Field Requirements section of the EMC manual  
  1889.   for appropriate  Format  File  entry  instructions.                        
  1890. .PA
  1891. >6908
  1892.                                                                          
  1893.   Mode Indicator:  This field defines the type of  EMC Batch File  that 
  1894.   will be created in the Create Electronic Claims option for the EMC 
  1895.   Receiver.  During your initial subscription period with the EMC 
  1896.   Receiver,  the EMC Batch Files you submit will be considered tests. 
  1897.   Once you have submitted error free a predetermined number of claims, 
  1898.   the EMC Receiver will allow you to begin submitting production claims.  
  1899.   Using  the  left  and right arrow, switch this setting from TEST to 
  1900.   PROD depending upon your needs for the EMC Receiver.                                                          
  1901. .PA
  1902. >6909
  1903.                                                                          
  1904.   Phone Number:  This is the number for  dialing  during an  EMC Batch 
  1905.   File transmission session to the selected EMC Receiver.  Enter  all 
  1906.   numbers required for making  this  call  (Enter  1 + Area Code + Number  
  1907.   for long distance). Do not enter any punctuation (i.e. 1(800)555-1212 
  1908.   ext 245 should be entered as 18005551212245).                                          
  1909. .PA
  1910. >6910
  1911.                                                                          
  1912.   Serial Port:  The  EMC  program must know where to access your modem. 
  1913.   Whether you are using an  internal modem  which requires the port 
  1914.   definition to be made on the modem card;  or are plugging  an external 
  1915.   modem into a socket on the back of the computer, the theory is the 
  1916.   same. COM 1, 2, 3, or 4 may be selected by pressing the left or right 
  1917.   cursor control arrow until the  correct  port  number  appears  on the  
  1918.   screen.  In the case of an internal modem, the communications port by 
  1919.   which the modem is addressed is defined by  switches or jumpers on the  
  1920.   modem board.  Consult your modem manual for the correct setting. The  
  1921.   switch or  jumper  settings must  match  the  communications  port  
  1922.   defined  in  this  field.      
  1923. .CO Serial Port
  1924.   After setting this field you can press the  [F9]Modem Test function key
  1925.   to  test  the  currently  selected  COM  port.                         
  1926.   NOTE: Be certain that only one device (modem, mouse, serial port, etc.)
  1927.   is configured on the selected COM port. Unpredictable results may occur
  1928.   if  two  or  more  devices  are  trying  to  share  the  same  port.   
  1929.   Also, be certain that you do not have  multiple communications software
  1930.   loaded and trying to access the same  COM  port ( running  Fax software
  1931.   in  the  background ).                                                 
  1932. .PA
  1933. >6911
  1934.                                                                          
  1935.   Baud Rate:  The  Baud Rate is most loosely translated as the speed of 
  1936.   the modem. You must contact a representative of the particular  EMC 
  1937.   Receiver for details on the fastest allowed modem speeds at the EMC 
  1938.   Receiver.  Then, you must determine the fastest speed allowed by your 
  1939.   modem, (Usually  your  modem  name  will  include / indicate  the top  
  1940.   speed).  Then  you  must  use the right and left arrows to set this 
  1941.   field on the lesser  of  the  two  speeds.                                          
  1942.  
  1943.   NOTE:  You  may  communicate  with  an EMC Receiver only as fast as the
  1944.   slowest modem.                                                         
  1945. .CO Baud Rate
  1946.   If you have a 14.4k  modem you will definitely be able to set the  Baud
  1947.   Rate  at 19,200.  You may be able to increase that setting to 38,400 if
  1948.   your modem has  "v.32" or "v.42" data compression.  Remember, both ends
  1949.   of the  communication must have data compression to achieve such a high
  1950.   rate.  If you have a 28.8k modem you may be able to achieve a data rate
  1951.   as  high  as  57,600 ( Only  if  the  other  end  can  do  it  too !). 
  1952. .PA
  1953. >6912
  1954.                                                                          
  1955.   Your Modem Dialing PREFIX:  These  characters  are  sent  to the modem  
  1956.   before  the phone number.  This  character sequence must have at a 
  1957.   minimum ATDT.  If you only have rotary  (pulse)  dialing,  enter  ATD.                                 
  1958.  
  1959.   Note:  alphabetic characters MUST be entered as uppercase letters only.
  1960. .CO Dialing PREFIX
  1961.                                                                          
  1962.   This  character  sequence  may be used to control a  PBX system or even
  1963.   access  a  long distance  dialing  service.  A comma is inserted in the
  1964.   character  sequence  to  instruct the modem to pause before dialing the
  1965.   next number  in  the string.  Each comma represents a one second pause.
  1966.   A  sample  telephone  number  to allow the modem to get an outside line
  1967.   on  a  tone  dialing  capable  PBX  system  is  as  follows:           
  1968.                 ATDT9,,                                                  
  1969.   This example dials a  9  to gain access to an outside line,  pauses two
  1970.   seconds and then dials  the  phone  number  entered in the phone number
  1971.   field above.  The pause  may be adjusted up or down by adding or taking
  1972.   away  commas  to  meet  the requirements of an individual phone system.
  1973. .CO Dialing PREFIX
  1974.                                                                          
  1975.   An  example  dialing prefix for a tone capable  PBX system using a long
  1976.   distance  dialing  service  which  requires  entry of an account number
  1977.   before  the  area  code  and  phone  number  is  as  follows:          
  1978.                    ATDT 9,,5551234,,,123456                              
  1979.   This example dials 9 for an outside line,  pauses for 2 seconds,  dials
  1980.   the long-distance service (5551234),  pauses for  3  seconds  and dials
  1981.   the  account  number  (123456).  The number entered in the phone number
  1982.   field is then dialed.                                                  
  1983. .PA
  1984. >6913
  1985.                                                                          
  1986.   Modem Dialing SUFFIX:  This  character  sequence  is  normally  used to 
  1987.   end the entire dialing sequence  before the carriage  return.  When the 
  1988.   MediSoft Direct program dials a number the Modem Dialing Prefix, Phone 
  1989.   Number and Modem Dialing Suffix are all sent to the modem at once in 
  1990.   this  order.    
  1991. .PA
  1992. >6914
  1993.                                                                          
  1994.   Modem Deinitialization:  By default this field is blank to indicate no 
  1995.   modem sequence is sent to the  modem  after  each  transmission.  You  
  1996.   may  find  it necessary to reinitialize  the  modem  after  your  
  1997.   MediSoft transmission session is complete.                          
  1998. .PA
  1999. >6915
  2000.                                                                          
  2001.   Connection Attempts:  Enter the number of times the Transmit Electronic 
  2002.   Claims option should attempt to reconnect with a receiver in the event 
  2003.   busy signals, failed connections or disconnections.  Enter '0' for  
  2004.   unlimited  attempts. 
  2005.   
  2006.   Note: MediSoft will make an unlimited number of attempts, regardless of
  2007.   this  setting  when  you  have  selected  a  Delayed  Transmission.    
  2008. .PA
  2009. >6916
  2010.                                                                          
  2011.   Receiver Type:  Tells  MediSoft  how  to  handle  the  Create  
  2012.   Electronic Claims option.  If you select "Direct Receiver", MediSoft 
  2013.   will not allow you to enter a range of Insurance Carriers. This is done 
  2014.   because MediSoft will process only those patients whose primary insurer 
  2015.   matches the  Direct Receiver/Insurance Carrier selected.  If you  
  2016.   select "Clearing House", MediSoft will allow you to enter a range of  
  2017.   Insurance  Carriers.  MediSoft will process those acceptable patients 
  2018.   whose primary insurance carrier falls within the range of insurance 
  2019.   carriers you have selected. MediSoft will skip any patients whose 
  2020.   primary insurance carrier is also defined with EMC Settings (MediSoft 
  2021.   assumes that patients transactions will be filed directly with the 
  2022.   insurance carrier, and not through a clearing house).
  2023. .PA
  2024. >6917
  2025.  
  2026.   Batch Method:  This field lets you define how to "batch" or group your 
  2027.   claims within the EMC file. It is recommended that you batch by attend-
  2028.   ing provider if you are billing for a group of providers.  Batching by 
  2029.   assigned provider is useful in a single provider practice, so that you 
  2030.   may have one claim for the patient instead of seperate claims for each 
  2031.   location they were seen at.  Batching by insurance company is only 
  2032.   recommended for certain carriers.  Call MediSoft Technical Support if 
  2033.   you think you need to batch by insurance company. 
  2034. >6918
  2035.                                                                          
  2036.   BBS Submitter ID:  As the name implies, this field is used to store a
  2037.   Submitter ID assigned by the selected EMC Receiver for access to a BBS
  2038.   system provided by the EMC Receiver.  However, you should refer to the
  2039.   MediSoft  Field Requirements section of the EMC manual for appropriate
  2040.   Format  File  entry  instructions.                                     
  2041. .PA
  2042. >6919
  2043.                                                                          
  2044.   BBS Password:  As the name implies,  this field  would most likely be 
  2045.   used to store a Password to the BBS for the selected EMC Receiver.  
  2046.   However, you should refer to the MediSoft Field  Requirements  section
  2047.   of the EMC  manual for  appropriate  Format  File  entry  instructions.
  2048. .PA
  2049. *
  2050.